5.0 Dimensions and Fixings
© Baxi Heating UK Ltd 2014
360° Orientation
Flue Ø 100mm
D
C
B
A
E
G
F
At least 1.5°
H
Heating
Return
(22mm)
Heating
Flow
(22mm)
Pressure Relief
Valve
(15mm)
Gas
Inlet
(22mm)
130 mm
130 mm
65 mm
Condensate
Drain
32.5 mm
Tap Rail
Dimensions
A 780mm
B 345mm
C 450mm
D 116mm Ø Min.
E 185mm
(207mm for 80/125mm
flue systems)
F 145mm
G 131mm
H 180mm