- 14 -
6.7Running data query and setting
Long press button to enter parameters query state, in the query conditions click the button to enter
parameter setting state, combined with and button to change the parameter value, press button again
to determine modification, During the parameter query condition press the button to return the main interface;No
operation is retained in the query condition.
Special note:
During Automatic mode, the icon is displayed;
During Cooling mode, icon is displayed ;
During Defrosting , icon is displayed;
During Heating mode, icon is displayed;
ICONS are used to identify the WIFI signals, its twinkle when its not connect with the server; its keeps on means
connection well .
7、System Parameter:
Parameter
Meaning
Range
Default
Remarks
P00
Memory function
0No\1Yes
1
Adjustable
P01
Operate at set time everyday
0No\1Yes
1
Adjustable
P02
Water temperature difference back
to restart
2-10
3
Adjustable
P03
Water Temperature difference to
stop
0-3
0
Adjustable
P04
Defrosting interval
30-90Min
40Min
Adjustable
P05
Defrosting on temperature (evaporator
coil temperature)
-30—0
-3
Adjustable
P06
Defrosting exit temperature
(evaporator coil temperature)
2-30
13
Adjustable
P07
Defrosting exit time
1-15Min
8Min
Adjustable
P08
Gas exhaust temperature protection
value
95-120
118
Adjustable
P09
Max. water set temperature
40~65
40
Adjustable
P10
Water pump operation mode
0Special\1
Normal
1
Adjustable
P11
Water pump stop time after reaching
water set temperature
3-20min
15
Adjustable
P13
Heating/Cooling option
0(Single cooling)/
1
Adjustable