9
Above a, b, c three parameter default data was fully considered by designer according to the
actual use. Generally users don't need to adjust. Please must be refer to battery supplier's
suggestion, or the battery will be damaged or irreparable destroy.
d) Load Working Mode Selection
The control default load working 24hours. When the load working time set to 24hours, the load will
keep working 24hours in no fault status. When the load working time set to less than 23Hours, it
means the load start timer or sensor function. If the battery capacity is enough, the load will be
started at sunset. The load will work under timer setting hours or stop working till sunrise.
Load mode
When the load join into timer or sensor mode, if the reset working time more than actual night
time, the load output will be closed at sunrise, although the working time is not reach to setting
hours, for example, the local actual nighttime is 10hours, user reset the working time at night is
12hours, but 10hours later the output will be closed automatically, the balance hours will be back
to zero. The load will be working with next sunset signal.
e) System Voltage Select
This parameter designed for customers wide range voltage requiring, the default display "UTO
system voltage 12V/24V Auto.
When battery voltage is more than 18Vt the controller will be auto change to 24V system with 24
control data.
When battery voltage is less than 18V, the controller will be auto change to 12V system with 12V
control data.
If the system voltage is set to "q", the controller will be work under 12V version forever. The battery
voltage is not valid. The reset data will be working after reconnection.
If the system voltage is set to "2", the controller will be work under 24V version forever, The battery
voltage is not valid. The reset data will be working after reconnection.
System voltage select