PrimeLog User Manual
17
2.2 Appendix 2: Specifications
Inputs: Single, 2 and 4 channels
Dedicated models:
Single channel flow
Single channel pressure
2-channel flow & pressure
4-channel flow x 2, pressure x 2
General purpose:
2-channel - 1 each analogue & digital
4-channel - 2 each analogue & digital
Digital channels:
Frequency: 0 - 500 Hz max
Bi-directional: YES - 2 pins provided
Conversion: 10 point table
Compatibility: Volt-free contact/open drain FET
Socam / Meinecke RO1.1 / OPTO 06
Kent PU100/HRP/BPG10
Schlumberger DS/S/TLOS
Combination Meters
Electromagnetic Meters - ABB/ Krone /
Fisher Porter
Insertion Meters - Quadrina MEP / QEP,
ABB Aquaprobe
Analogue channels:
Voltage: 100 mV, 0.5 V, 1.0 V, 5.0 V, 10 V
Current: 10 mA, 20 mA, 4 - 20 mA
Pressure: 350 mBar - 20 Bar (3.5 m - 200 m)
Accuracy (20°C): 0.1% or 0.5% of range
Dedicated pressure
channel:
Range: 3 - 25 Bar
Accuracy (20°C): 0.5% of range
Auto Zero: On site (by Psion Workabout)
Outputs:
Alarm: One per channel
Local comms: 19200 baud
Modem comms: 2400 baud (V.22bis)
Local readout: by Psion Workabout
Memory retrieval: All data / data since last read / defined data
Logging:
Types: Count
Modes: Cyclic / start-stop / stop when full
Capacity: 128 Kbytes (approx 1 year at 15
minutes/channel)
Interval: 1 second - 24 hours
Features: Independent logging per channel
Modem: Available on all models
Power: