Diode test
0-3V
0.001V
Forward DC current:
approximately 1mA;
Open-circuit voltage:
approximately 3.2V. The
display unit shows the
approximate value of the
diode's forward voltage
drop.
Overload protection: 600V DC/AC 4.2.6
Beeper continuity
Functions
Measuring
range
Resolution
Description
Testing
conditions
600
0.1
Buzzer sounds , the
resistance is less
than
30Ω
Open-circuit
voltage:
approximately
1V
Overload protection: 600V DC/AC 4.2.7
Capacitor
Measuring range
Resolution
Accuracy
1nF
0.001 nF
±(4% Reading +30 digits)
10nF
0.01 nF
±(2.5% Reading +10 digits)
100nF
0.1 nF
1uF
0.001uF
10uF
0.01 uF
100 uF
0.1uF
1mF
0.001m F
60mF
0.01mF
±(5% Reading +30 digits)
Overload protection: 600V DC/AC