0
MT-1707
3-5/6 True-RMS Digital Multimeter
Question and Answer IconNeed help?

Do you have a question about the Pro's Kit MT-1707 and is the answer not in the manual?

Pro's Kit MT-1707 Specifications

General IconGeneral
TypeDigital Multimeter
Diode TestYes
Continuity BuzzerYes
Data HoldYes
Measurement FunctionsDC/AC Voltage, DC/AC Current, Resistance, Capacitance, Frequency, Diode, Continuity
DC Current Range10A
AC Current Range10A
Resistance Accuracy+/-(0.8%+3)

Summary

General Information

Safety Information

Covers essential safety instructions and considerations for operating the multimeter.

Safety Instructions

Details standard safety procedures, including protection against electric shock and unintended use.

Safety Considerations

Highlights factors affecting meter stability and safe operation near conductors or damaged equipment.

General Information

Safety Symbols

Explains the meaning of various safety symbols found on the meter and in the manual.

Maintenance Practices for Safety

Outlines crucial safety steps during maintenance, such as disconnecting test leads.

General Information

Input Protection Measures

Details the meter's capacity to withstand input voltages and protect against overload.

Schematic Diagram for the Meter

Physical Appearance

Identifies and labels the physical components and features of the multimeter.

Description of Symbols on the Display Unit

Description of Functional Keys

Description of Input Sockets

Accessories

Operational Guidelines

Normal Operation

Covers basic operational modes like Hold, Backlight, LED Light, and Auto Power Off.

Measurement Guidelines

Provides instructions for performing various types of measurements with the multimeter.

Operational Guidelines

Measurement of AC Voltage and DC Voltage

Details the procedure for measuring AC and DC voltages, including safety precautions.

Operational Guidelines

Frequency Measurement

Explains how to measure frequency using the Hz% and ACV positions.

Operational Guidelines

Electric Resistance Measurement

Guides on measuring electric resistance, including safety and accuracy tips.

Operational Guidelines

Diode Test

Describes the process for testing diodes, emphasizing safety and proper connection.

Beep Continuity Test

Details how to perform a continuity test using the beeper function.

Operational Guidelines

Capacitance Measurement

Explains the procedure for measuring capacitance, including safety for large values.

Current Measurement

Covers measuring DC and AC current, with crucial warnings about fuses and safety.

Operational Guidelines

NCV Test (Non-contact Voltage Detection)

Explains how to perform non-contact voltage detection and its indicators.

Measuring Temperature

Guides on using the K-type thermocouple to measure temperature.

Technical Parameters

Overall Parameters

Lists environmental operating conditions, altitude, temperature, and humidity limits.

Precision Indicator

Details accuracy specifications, warranty, and reference conditions for measurements.

Technical Parameters

DC Voltage

Specifies measuring ranges, resolution, accuracy, and input impedance for DC voltage.

AC Voltage

Specifies measuring ranges, resolution, accuracy, and input impedance for AC voltage.

Technical Parameters

Frequency (at AC Positon)

Lists specifications for measuring frequency in AC voltage mode.

Electric Resistance

Details measuring ranges, resolution, accuracy, and overload protection for resistance.

Diode

Specifies testing conditions, resolution, and forward voltage for diode measurements.

Technical Parameters

Beeper Continuity

Details testing conditions and resolution for the beeper continuity function.

Capacitor

Lists measuring ranges, resolution, accuracy, and overload protection for capacitance.

Technical Parameters

Frequency

Provides specifications for measuring frequency across various ranges.

Duty

Specifies the measuring range, resolution, and accuracy for duty cycle measurements.

DC Current

Details measuring ranges, resolution, accuracy, and protective tubes for DC current.

Technical Parameters

AC Current

Details measuring ranges, resolution, accuracy, and protective tubes for AC current.

Temperature

Specifies measuring ranges, resolution, and accuracy for temperature readings.

Meter Maintenance

General Maintenance

Covers cleaning procedures for the meter's exterior and input sockets.

Meter Maintenance

Battery & Fuse Replacement

Guides on safely replacing batteries and fuses, including warnings.