EasyManua.ls Logo

probst VPH-150 - Maintenance and Care; Routine Maintenance Schedule

probst VPH-150
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance and care
VPH 150
V5
10/01/13
16 / 23
6 Maintenance and care
6.1 Maintenance
To ensure the correct function, safety and service life of the device the following points must be executed in
the maintenance interval.
Attention
Take care that for all maintenance services the device is completely shut down!!
MECHNICAL
Service interval
Maintenance work
First inspection after
25 operating hours
Control and tighten all screws and connection.
(The implementation is only allowed by an expert).
All 50 operating hours
Tighten all screws and connection (Take care that the tightening torques
according to the property class of the screws are observed).
Check all joints, bolts, guidance’s and gears for correct function, if
necessary adjust or replace it.
Check all Grippers ( if available) for signs of wear.
Grease all slidings ( if available) when the device is in opened position
with a spatula.
Minimum 1x per year
(at rough conditions
shorten the interval)
Check of all the suspension parts, bolts and straps. Check for corrosion
and safety by an expert.
6.1 Suction plate
Clean all bits, dirt and dust from the suction plate at least
once a day. Replace any damaged or worn-out suction
Plates (splits, holes, distortions) immediately.
Do no use petrol or corrosive fluids which would
destroy the suction hose or make it leaky.