13HPX900/1200/2400/2800InputBoard
13.1CircuitDiagramofInput
13.2MalfunctionAnalysisonInputBoard
Sequence
No.
CircuitFunction Failure
1
Stereo/Parallel
/BridgeSwitch
Circuit
Poorconnection in SW1will cause theparallel and bridge indicator
doesnotshine;
PoorconnectioninSW1willcausednooutputinonechannelwhen
amplifierinstereo,parallelorbridgemode;
2
BassBoost
Circuit
PoorconnectionofSW2willcausenobassincreaseinCH1orCH2
Whenincreasethebasswillcausethesounddistortion;
3
Sensitivity
SwitchCircuit
Poor connection of SW3 will cause the unbalanced output of left
andrightchannels;
4 ClipLimitCircuit
No limit in CH1 or CH2 caused by the damage of L1, L2 linear
photoelectricalcoupler;
There is still larger signal output after start protection
functionbecauseVR1/VR2isnotinthebestvalue;
5
±15V
powersupply
Power supply imbalance in +15 V or‐15V will cause a serious
distortion when volumeincreased,poweramplifieriseasy to go into
protectionfunction;