8
Maintenance
Never service heater
while it is plugged in
or while hot!
USE ORIGINAL EQUIPMENT REPLACE-
MENT PARTS. Use of third-party or
other alternate components will void
warranty and may cause unsafe
operating conditions.
FUEL TANK
Flush every 200 hours of operation or as
needed (See Long-term Storage, page 7).
AIR INTAKE FILTER
WASH AND DRY WITH SOAP AND
WATER EVERY 500 HOURS OF
OPERATION, OR AS NEEDED.
- Remove screws along each side of
heater using medium Phillips
scre
wdriver.
- Lift off upper shell.
- Remove fan guard.
- Wash or replace air intake filter.
- Reinstall fan guard and upper shell.
REPLACE EVERY 500 HOURS OF
OPERATION OR ONCE A YEAR
- Remove upper shell and fan guard
(See Air Intake Filter Figure 13).
- Turn air pressure gauge counter-
clockwise and remove.
- Remove end filter cover screws using
medium Phillips screwdriver.
- Remove end filter cover.
- Replace air output and lint filter.
- Reinstall end filter cover and air
pressur
e gauge.
- Reinstall fan guard and upper shell.
FAN BLADES
CLEAN EVERY SEASON OR AS NEEDED
- Remove upper shell (See Air Intake
Filter).
- Use M6 Allen wrench to loosen set
screw which holds fan blade to motor
shaft.
- Slip fan blade off motor shaft.
- Clean fan blade using soft cloth
moistened with kerosene or solvent.
- Dry fan blade thoroughly.
- Reinstall fan blade to motor shaft.
- Place fan blade hub flush with end of
motor shaft.
Figure 13 – Air Filter Access
Figure 14 – Filter Assembly
ProFitter
TM
Portable Oil-Fired Heaters
- Make sure storage place is free of dust
and corrosive fumes.
- Store the heater in the original box
with the original packing material and
keep USER’S MANUAL with heater.
Figure 12 - Drain Bolt
Fuel Drain Bolt
Seal
6. Store heater in dry well ventilated
area. Make sure storage place is
free of dust and corrosive fumes.
7. Store the heater in the original box
with the original packing material
and keep the USER’S MANUAL
with the heater.
ProFitter
TM
Operating Instructions and Parts Manual
For Technical Support or Troubleshooting, Call: 1-877-447-4768, 8:30 am - 4:30 pm CST www.ghpgroupinc.com
KFA50PF, KFA75PF, KFA125PF,
KFA170PF and KFA210PF
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
IMPORTANT : Do not store kerosene
over summer months for use during
next heating season. Using old fuel
could damage heater.
4. Reinstall fuel cap. Properly dispose
of old and dirty fuel. (For Models
KFA50PF, KFA75PF Only)
5. Reinstall Fuel Drain Bolt to Fuel tank
and tighten firmly using 3/4” socket or
adjustable wrench.
(For Models KFA125PF, KFA170PF,
KFA210PF Only)
Screw
Upper Shell
Air Intake Filter
Fan Guard
AIR OUTPUT FILTER, LINT FILTER
Air Output
Filter
Cover
End Filter
Air Intake
Filter
Screw
Air Pressure Gauge
Lint Filter