MODELLING LAMP(4)
The modelling light consists of a lamp that is fed directly
from the mains. It is therefore important to check that
the lamp has a rated voltage that matches that of the
mains.The lamp supplied as standard is a 150- 250W
halogen lamp with an E27 base (ComPact Special 300
and ComPact Special 600) or a 500W halogen lamp with
an E11 Minican base with the ComPact 1200.
The ComPact 300and ComPact 600 can also be
supplied with a normal100Wlamp with an E27 base.
To improve the correspondence between the modelling
light and flash, the flash tube and modelling lamp is
enclosed in a frosted glass cover (standard in all models
with halogen modelling lamps).
BEFOREYOU CHANGETHE MODELLING LAMPOR
FLASHTUBE, DISCHARGETHE POWER INTHE UNIT
BY PRESSINGTHETESTBUTTONATTHE SAMETIME
AS SWITCHING OFFTHE MAIN SWITCH.
READYLAMP/TESTBUTTON (5)
The ready lamp/test button has two functions. First, it
lights up when the unit is fully charged. Second, it can
be used to manually sync (trigger) the unit (open flash).
When a lower energy settingis chosen , trigger a flash
so that the unit can recycle forthe new energy setting.
PHOTOCELL
The units has a built-in photocell.The photocell in
the unit servesas a slavesync when another flash is
triggered.The photocell is automatically disabled
when a sync cable is plugged in.