Assembly and connection manual | Agrónic 4500
Voltage 12 Vdc - 24 Vdc
Energy consumption Less than 12 W
Fuse Entrance Thermal (PTC) 1,1 Amp. at 25 °C, self-resetting
Overall power supply
Voltage From 12 a 24 Vdc ó Vac (maximum 30 V)
Fuse “R+” input Thermal (PTC) 6,0 Amp. at 25 °C, self-resetting
Power supply outputs
Memory
Without maintenance, 10 years for parameters, programs and registers in memory in FLASH
memory.
Clock 10 years without power
Memory Backup and Clock
Digitals
Number 24, expandable to 40, 56, 72, 88 and 104.
Type By relay contact, with 24 Vac potential (external transformer).
Límits 30 Vac / 30 Vdc, 1 Ampere, 50-60 Hz, CAT ll (per ouput)
Analog /
Pulsed
(option)
Number 5 or 10
Type 4-20 mA (with galvanic isolation)
All the outputs have double insulation with respect to the network input.
Outputs
Temperature -5 °C a 45 °C
Humidity < 85 %
Altitude 2000 m
Pollution Grade 2
Atmosphere
Box model De 3,2 kg a 6,3 kg
Built-in model De 4,0 kg a 5,0 kg
Weight
This symbol indicates that electrical and electronic equipment must not be disposed of with household waste at the end
of its useful life. The product must be taken to the corresponding collection point for recycling and proper treatment of
electronic equipment in accordance with national legislation.
Digital
sensors
Number 12
Type Optocoupled, operate at 12 ot 24 Vcc/Vac
Analog
(option)
Number 5 ó 10
Type 4-20 mA, (with galvanic isolation)
Number 1 ó 2
Type 0-20 V (with galvanic isolation)
Inputs
It complies with Directive 89/336/CEE for Electromagnetic Compatibility and Low Voltage Directive
73/23/CEE for Product Safety Compliance. Compliance with the following specifications was
demonstrated as indicate in the Oicial Journal of the European Communities.
Declaration of conformity
Protective Earth
terminal
Danger, risk of
electric shock
Ground Terminal Double insulation
Symbols that may appear on the product
2 TECHNICAL CHARACTERISTICS