6
Specification
EVA-22D-SE-RFID / EVA-22D-SE-RFID-C
IP65
-25ºC~+50ºC
0-95% non-condensing
Natural air cooling
8W
IK10
Protection degree
Environment temperature
Relative humidity
Cooling
Standby power consumption
IK Rating
Working Environment
Protection
Over voltage protection
Under voltage protection
Over load protection
Short circuit protection
Earth leakage protection
Over-temp protection
Surge protection
PEN fault protection
Anti tamper Switch
Function & Accessory
Yes
Yes/Yes/Opt.
Type 2 (socket)
2
LCD
Ethernet/WIFI/4G
Outlet Type
Number of outlets
RCBO
LED Indicator light
Mid Metering
Emergency stop button
RFID
Dynamic Load Management
Modbus Meter Only
(EV-TPM)
Type A +6mA DC fault
current protection
(Equivalent to Type B)
CE
SA8000 Accredited
OZEV Approved
UKCA
Certification
Mechanical
320/1635/175mm
30KG
Opt. EV-GMEVA-D-2
600/600/400mm
Opt. EV-TPM-200A
Ground-mounting
Recommended base size (W/H/D)
Dynamic Load Management
Dimension (W/H/D)
Weight
Mounting & Accessories
Input Amps
Input voltage
Input frequency
Output voltage
Max. output power
Max. output current
Charging interface type
63a Three Phase
415V AC
50HZ
415V AC
22KW per socket
32A per socket
IEC 62196-2, Type 2
Input & Output
310
1637
160
30
230
110
15.5
EVA-07D-SE-RFID-C
Model Only