ERROR
SOURCE
ERROR TYPE ERROR DETAIL
INTELLI-IQ FIRMWARE
UPDATE
The system is updating its rmware. Please do not turn off any
device in the network and wait until the process is complete.
This process may take up to 15 minutes for a major update that
includes a graphic library update.
OVERHEAT The system is overheating and will shut down soon to protect
itself. Please let the device cool down before using it again.
DEVICE ERROR A connection problem has occurred on the LIN network. Please
check the hardware connections and wait for IQD2 to detect the
network automatically. This process takes about one minute.
AUXILIARY
BATTERY
SHORT CIRCUIT The auxiliary battery has a short circuit problem. Please x the
issue before the battery gets damaged.
OVERVOLTAGE The battery voltage is over 16.5V, which is too high. Please check
the battery pack setup. The charging system will stop charging if
the voltage is above the limit.
REVERSE
CONNECTION
The auxiliary battery is connected in the wrong way, which can
harm other devices. Please disconnect and check the battery or it
will not be charged.
FAULTY BATTERY The battery is faulty and does not work well after charging.
Please replace the battery in the system.
NO BATTERY
CONNECTED
The charging system cannot detect an auxiliary battery.
Please make sure the connection is secure.
ALTERNATOR
INPUT
OVERVOLTAGE The alternator input voltage is too high and exceeds the limit
of 32.5V, which stops the charging process. Please remove and
make sure the source voltage is within the operating range.
REVERSE
CONNECTION
The alternator input is connected in the wrong way, which can
damage the charging system. Please disconnect and inspect the
input to avoid any harm.
SOLAR INPUT OVERVOLTAGE The solar input voltage is too high and exceeds the limit of 32.5V,
which stops the charging process. Please remove and make sure
the source voltage is within the operating range.
REVERSE
CONNECTION
Solar input is connected in the wrong way, which can damage
the charging system. Please disconnect and inspect the input to
avoid any harm.
IDCX OVERHEAT The charging system is affected by high ambient temperature,
which reduces the charging performance. The charging process is
still continuing within a safe range.
LOW VOLTAGE
& CRITICAL LOW
VOLTAGE
The supply voltage is not enough to charge the battery. Please
check the input source, such as the alternator or the solar panel,
to ensure they provide enough voltage to start the charging
process.
11