EasyManuals Logo

Proline KECOM48 User Manual

Proline KECOM48
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #20 background imageLoading...
Page #20 background image
16 |
troubleshooting
NOTHING WORKS (Control Panel not lit, Blower not working)
Solution 1: Turn on power at circuit breaker panel or fuse box. Check for
tripped breaker or blown fuse.
Solution 2: Make sure hood main power switch is on.
LIGHTS NOT TURNING ON
Solution 1: see “nothing works”
Solution 2: Swap out lights to determine if bulbs are defective.
RANGE HOOD VIBRATES WHEN BLOWER IS ON
Solution: Make sure the range hood has been secured properly to the ceiling
or wall.
BLOWER SYSTEM SEEMS WEAK
Solution 1: Increase the fan speed, ensure that it is at a high enough setting.
Solution 2: Make sure the ducting is sized correctly. Range hood will not
function efficiently with insufficient duct size (IE, 9” duct over 8” hole)
Solution 3: Check to see if duct is clogged or if damper unit (half-circular
flapper) is installed incorrectly. A tight mesh on a side wall cap unit might
also cause restriction to the air flow.
AIR NOT VENTING OUT PROPERLY
Solution 1: Make sure there is at least 28” (71 cm) between the stove top
and the bottom of the hood
Solution 2: Reduce the number of elbows and length of duct work. Check to
ensure all joints are properly connected, sealed, and taped.
Solution 3: Make sure power is on high speed for heavy cooking.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Proline KECOM48 and is the answer not in the manual?

Proline KECOM48 Specifications

General IconGeneral
BrandProline
ModelKECOM48
CategoryVentilation Hood
LanguageEnglish

Related product manuals