be replaced.
S
ERVICE OPERATIONS
WARNING
Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacturer.
The appliance shall be stored in a room without continuously operating ignition
sources (for example: open øames, an operating gas appliance or an operating
electric heater.
Do not pierce or burn.
Be aware that refrigerants may not contain an odour.
Appliance shall be installed, operated and stored in a room with a øoor area larger
than 8 m
2
.
Installation (Space)
The installation of pipe-work shall be kept to a minimum;
Pipe-work shall be protected from physical damage and shall not be installed in
an unventilated space;
Compliance with national gas regulations shall be observed;
Mechanical connections shall be accessible for maintenance purposes;
Minimum øoor area of the room: 8 m
2
Maximum refrigerant charge amount (M): 0,14kg
keep ventilation openings clear of obstruction;
Servicing shall be performed only as re
commended by the manufacturer.