This formula yields a close approximation of the starting load of your appliances.
Most often the start-up load of the appliance or power tool determines whether the inverter has the capability to
power it.
CAUTION
Know the wattage requirement of your appliances. Use only those appliances that do not exceed the capacity of
this unit.
The output waveform of this inverter is a MODIFIED SINE WAVE. It has a total harmonic distortion of 28% and
maximum single harmonic of 18%. If you choose to measure the AC output voltage, you must use a TRUE RMS
VOLTMETER such as a Fluke 8060A, Fluke 87, Triplett 4200, Beckman 4410 or any “True RMS” multimeter. Using
any other type of voltage measuring device will result in an AC voltage reading of 20 to 30 volts lower than the rated
value.
CAUTION: Do not use this Powerstation with devices that may be harmed by the inverter’s modified sine wave
output (non-sinusoidal), including, but not limited to, appliances with speed controllers (like power tools). Metal
halide arc (MHI) lights can also be damaged.
NOTE: If you're unsure about using the inverter to power a device, contact the equipment manufacturer to confirm
if the appliance is compatible with the modified sine wave (non-sinusoidal) AC waveform.
1.2
Operating Instructions
Make sure the Powerstation is fully charged before use.
Long press the Power (ON/OFF) button to turn on the power station. (Long press again to turn off the power
station)
Short press the AC button to activate the AC output function when the power station is on. The LCD screen will
then display the voltage, power, frequency, and AC status.
8