Monitoring the System
Tsunami MP-8100 Installation and Management Guide 163
3. After setting the event log priority option, click Show Event Log to display the event logs.
To delete the Event Log, click Clear Event Log.
NOTE: The recent eventlogs are stored in the flash memory.
6.7.2 Syslog
System log messages are generated by the system by sending requests at various instances to the system log server.
Figure 6-16 System Log
Click Show System Log to display SYSLOG information.
Click Clear System Log to clear the SYSLOG information.
6.7.3 Temperature Log
This feature reports and logs the internal temperature of the unit. When the internal temperature value reaches the minimum
threshold value of -40ºC or the maximum threshold temperature of 60ºC, the internal temperature is logged and an SNMP
trap is sent (At 5 Degrees before each limit, the device issues a warning trap). These threshold temperature values may be
reconfigured but the values cannot go beyond the default ones.