10 11
OUT1: ON
GRAPH EQ: ON
MUTE ALL (ENTER)
GRAPH EQ: ON
ON ALL [ENTER]
GRAPH EQ: ON
• Mute
The outputs can be switched individually on and o quickly by holding down the
HOTKEY key that corresponds to the output. The LED color indicates the status
of the output.
In the “MUTE” screen, you can sll
turn o and on all the output channels
simultaneously using the ENCODER go to
the output eld and select “ALL-ENTER”
or “ALL-ENTER ON”. Then fast touch on
ENCODER. You can also turn the input
graphic equalizer on or o.
BLUE LIGHT: OUTPUT ON / RED LIGHT: OUTPUT OFF (MUTE)
MAIN MENU
Graph EQ Presets
MAIN MENU
XOVER Presets
GRAPH EQ PRESETS
Loudness
XOVER PRESETS
OUT 1 <- FLAT
• Graphic Equalization Presets
The DSP2.8X oers 12 graphic equalizaon presets that are selected from the
“GRAPH EQ PRESETS ” in the main menu:
• FLAT • LOUDNESS • BASSBOOST • MID BASS • TREBLE BOOST
• POWERFUL • ELECTRONIC • ROCK • HIP HOP • POP
• VOCAL • PANCADAO (Heavy Beat)
• Crossover Presets
The processor oers 11 crossover presets that are selected from the “XOVER
PRESETS ” in the main menu, in this way it is possible to congure the frequency
cut of each output more quickly:
• SUBW1 • SUBW2 • SUBW3 • WOOFER1 • WOOFER2 • WOOFER3
• DRIVER1 • DRIVER2 • DRIVER3 • TWEETER • FLAT
COPY CHANNEL
Source: OUT1
COPY CHANNEL
Destination: OUT2
COPY CANNEL
NO [YES]
• Copy Channel
This funcon allows you to copy all audio sengs from one output channel to
another. The copied funcons are: parametric output equalizer, roung, crossover,
alignment, phase inversion, limiter, gain and mute.
I. Select an SOURCE output channel using the
HOTKEY hotkeys or by turning the ENCODER,
fasten ENCODER;
II. Select a DESTINATION output channel
using the HOTKEY shortcut keys or by turning
the ENCODER, fasten ENCODER;
III. A conrmaon message will appear. If
conrmed, as output channels from ORIGIN
to the DESTINATION output channel,
overwring as the DESTINATION output
channel.
• Save / Load / Factory Reset
The DSP2.8X has four memory slots available for saving personalized sengs,
accessed via the “SAVE” funcon. Saved sengs can be named with tles up
to 15-characters long. Besides the memory space available to the user, there
is autosave, where all parameters and sengs are saved in a separate working
To load previously saved sengs use
the “LOAD” funcon. This funcon also
allows the factory presents to be loaded
via the “DEFAULT” memory.
SAVE MEMORY1
Memory1
LOAD
Default
FACTORY RESET
NO [YES]
memory. Or rather, if there is a drop in
power or the product is turned o during
conguraon, the sengs will not be lost.
This funcon cannot be disabled.
If you want to restore all of the DSP2.8X factory sengs, simultaneously hold down the
HOTKEY shortcut keys for outputs 1, 2 and 3 while turning on the device.
This procedure will erase all internal sengs and saves.