Priming Pump
All suction and discharge valves must be open as well as filter air relief valve when starting the circulat-
ing pump system. Failure to do so could result in severe personal injury.
Priming Pump Placed Below Water Level
● The pump will prime itself if it is placed lower than the water level.
Priming Pump Placed Above Water Level - If water level is lower than the pump, then following
these instructions for priming. The suggested installation of the pump is 12” above the pool water
level. The pump should not be installed more than 30” above the pool water level.
Turn Power off to pool pump
Make sure pool water is halfway up pool skimmer face
Open suction valves
Open discharge valves
Open filters air release valve
Unscrew and remove pump lid
Remove any debris from pump basket
Clean pool filter if needed
Clean pool skimmer basket if needed
Fill pump strainer basket with water from garden hose
Clean and lubricate strainer cover O-ring each time it is removed. Inspect O-ring and place it
back on the strainer cover.
Turn the strainer cover clockwise to tighten. NOTE: Tighten the strainer cover by hand only.
NO wrenches.
Turn on the power to the pump and wait for the pump to prime. This may take up to five (5)
minutes. Priming time depends on the vertical length of the suction lift and the horizontal length
of the suction pipe. If the pump does not prime within five minutes, stop the motor and
determine the cause. Be sure all suction and discharge valves are open when the pump is
running.
Once the water starts coming out of the pool filter air release close pool filter air release
Helpful Videos for Pool Pump Priming
● Video on How to Prime a Pool Pump -
https://www.inyopools.com/HowToPage/how_to_prime_ a_pool_pump.aspx
● Video on How to Determine Why a Pool Pump Won't Prime -
https://www.inyopools.com/HowToPage/how_to_determine_why_a_pool_pump_won_t_prime.aspx
● Video on How to Identify and Correct Air Leaks -
https://www.inyopools.com/HowToPage/how_to_identify_and_correct_air_leaks.aspx
● Video on How to Correct Swimming Pool Plumbing Issues -
https://www.inyopools.com/blog/how-to-fix-priming-problems-in-your-pool-plumbing/
ATTENTION- Before removing strainer cover:
ATTENTION- Wait five seconds before re-starting the pump. Failure to do so may cause
reverse rotation of the motor and seriously damage the pump.
1. STOP PUMP before proceeding.
2. CLOSE VALVES in suction and outlet pipes
3. RELEASE ALL PRESSURE from pump and piping system using filter manual air relief valve.