Questions and Answers

  • C
    Cheryl ButlerAug 20, 2025
    Why is my Puretec Water Dispenser valve display blank?
    • D
      Donald GonzalezAug 20, 2025
      A blank screen on your Puretec Water Dispenser valve can be due to several reasons. It could be that the transformer isn't connected, there's no power at the outlet, the outlet is switched or providing improper voltage, the battery is dead, the transformer is defective, or the PC board is defective. To resolve this, ensure the transformer is connected, use a working outlet or repair the existing one, use an uninterrupted outlet and ensure proper voltage, replace the battery (CR2032), replace the transformer, or replace the PC board.
  • C
    Christopher SnyderAug 25, 2025
    How to fix Puretec SOL30-E3 time flashing on and off?
    • R
      Ryan MurrayAug 25, 2025
      If the time of day is flashing on and off on your Puretec Water Dispenser, it's likely due to a power outage. To fix this, reset the time of day, replace the battery (CR2032), and then perform a ‘dry’ reset.
  • D
    Donald HunterAug 26, 2025
    Why does my Puretec Water Dispenser valve regenerate at the wrong time?
    • D
      donnamooreAug 26, 2025
      If your Puretec Water Dispenser valve regenerates at the wrong time of day, it could be due to a few reasons: a power outage, the time of day being set incorrectly, or the regeneration time being set incorrectly. To resolve this, reset the time of day and replace the battery (CR2032) if needed, reset the time of day to the correct time, or reset the regeneration time. Also, check if you are using uninterrupted outlet.
  • G
    Gerald CooperAug 27, 2025
    What causes excessive water in the regenerant tank of my Puretec Water Dispenser?
    • S
      Sarah HendersonAug 27, 2025
      Excessive water in the regenerant tank of your Puretec Water Dispenser can be caused by several factors: incorrect program settings, a plugged injector, a loose or damaged drive cap assembly, a leak from the seal/spacer stack assembly, a restricted or kinked drain line, a plugged backwash flow controller, or a plugged refill flow controller. Solutions include contacting Puretec for assistance regarding program settings, cleaning or replacing the injector, tightening or replacing the drive cap assembly, cleaning or replacing the spacer stack assembly, checking the drain line for restrictions or kinks and addressing them, cleaning or replacing the backwash flow controller, and cleaning or replacing the refill flow controller.
  • M
    Michelle SparksAug 29, 2025
    What to do if my Puretec SOL30-E3 valve doesn't regenerate during manual regeneration?
    • S
      Savannah FarrellAug 29, 2025
      If your Puretec Water Dispenser valve doesn't regenerate when performing a manual regeneration, it could be due to: no power to the valve (refer to ‘No display/blank screen on valve.’), a broken drive gear or drive cap assembly, or a broken piston rod. To fix this, refer to ‘No display/blank screen on valve.’, replace the drive gear or drive cap assembly, or replace the piston rod.
  • L
    Lisa DavisAug 31, 2025
    Why Puretec Water Dispenser valve doesn't regenerate automatically?
    • D
      Diane RileyAug 31, 2025
      If your Puretec Water Dispenser valve regenerates manually but not automatically, the issue might stem from several causes: the bypass valve being in bypass position or faulty (turn bypass to normal operation or replace bypass), the meter loosely or not connected to PC Board (connect meter into the three pin connector labelled METER on PC Board), a restricted or stalled meter turbine (remove meter and check for rotation or foreign material), incorrect programming (contact Puretec for assistance), a defective meter (replace meter), or a defective PC Board (replace PC Board).
  • L
    Laura GoodwinSep 2, 2025
    How to troubleshoot Puretec SOL30-E3 Water Dispenser error E1?
    • J
      johngonzalezSep 2, 2025
      Error code E1 on your Puretec Water Dispenser indicates the control is unable to sense motor movement. This could be due to the motor not being fully inserted, broken or disconnected motor wires, an incorrectly installed PC Board, the board being unable to read the middle reduction gear, missing or damaged reduction gears, or a defective PC Board. To resolve this, disconnect power, ensure the motor is fully engaged, check for broken wires, and ensure the two-pin connector is connected to the PC Board. Also, ensure the PC Board is correctly clipped into the drive bracket, check the foil on the reduction gear for foreign material, replace any missing gears, or replace the defective PC Board. Finally, connect power and perform a 'dry' reset.
  • A
    Antonio WilliamsSep 4, 2025
    Why is my Puretec SOL30-E3 Water Dispenser using too much regenerant?
    • A
      Andrea ConradSep 4, 2025
      If your Puretec Water Dispenser control valve is using too much regenerant, it could be due to an incorrect refill setting, an incorrect program setting, or the valve regenerating frequently. Contact Puretec for assistance regarding the refill and program settings. Check for leaking fixtures or if the system is undersized.
  • P
    petersondanielSep 6, 2025
    What does Puretec Water Dispenser error E2 mean?
    • R
      Rebecca NewtonSep 6, 2025
      Error code E2 on your Puretec Water Dispenser means the control valve motor ran too short and was unable to find the next cycle position and stalled. This can be caused by foreign material lodged in the valve, mechanical binding, the main drive gear being too tight, or incorrect voltage being delivered to the valve. You can try cleaning or replacing the piston/spacer stack assembly, checking the piston, spacer stack assembly, drive bracket, and main drive gear interface, loosening the main drive gear, or checking the voltage of the power source. After addressing the potential cause, perform a 'dry' reset.
  • R
    rachel45Sep 8, 2025
    What does Puretec Water Dispenser error E3 mean?
    • T
      Tamara ReedSep 8, 2025
      Error code E3 on your Puretec Water Dispenser indicates that the control valve motor ran too long and was unable to find the next cycle position. This could be due to motor failure during regeneration, foreign material lodged in the valve, or the drive bracket not being correctly installed. To address this, check the motor connections, clean or replace the piston/spacer stack assembly, or correctly snap the drive bracket in place. After addressing the potential cause, perform a 'dry' reset.

Summary

Puretec Customer Service

Installation Record

Before Installation

Warnings

Essential safety precautions and guidelines for installation.

Specifications

Installation Procedure

Programming

Other Settings

Instructions for configuring hardness and day override settings.

Regeneration Mode

Explains how and when the system performs regeneration cycles.

Manual Regeneration

Procedures for initiating regeneration manually when needed.

Start-Up

Replenishment of Salt Supply

Troubleshooting Guide

Dry Reset Procedure

Initial troubleshooting step involving a system reset.