Questions and Answers

  • J
    Jennifer RossAug 20, 2025
    Why is my Puretec SOL40-E3 valve display blank?
    • R
      Russell GuzmanAug 20, 2025
      A blank screen on your Puretec Water Dispenser valve can be due to several reasons. It could be that the transformer isn't connected, there's no power at the outlet, the outlet is switched or providing improper voltage, the battery is dead, the transformer is defective, or the PC board is defective. To resolve this, ensure the transformer is connected, use a working outlet or repair the existing one, use an uninterrupted outlet and ensure proper voltage, replace the battery (CR2032), replace the transformer, or replace the PC board.
  • V
    vpattersonAug 25, 2025
    How to fix Puretec Water Dispenser time flashing on and off?
    • U
      uheathAug 25, 2025
      If the time of day is flashing on and off on your Puretec Water Dispenser, it's likely due to a power outage. To fix this, reset the time of day, replace the battery (CR2032), and then perform a ‘dry’ reset.
  • Z
    zhillAug 26, 2025
    Why does my Puretec SOL40-E3 Water Dispenser valve regenerate at the wrong time?
    • J
      Julie RoseAug 26, 2025
      If your Puretec Water Dispenser valve regenerates at the wrong time of day, it could be due to a few reasons: a power outage, the time of day being set incorrectly, or the regeneration time being set incorrectly. To resolve this, reset the time of day and replace the battery (CR2032) if needed, reset the time of day to the correct time, or reset the regeneration time. Also, check if you are using uninterrupted outlet.
  • K
    Kevin LewisAug 27, 2025
    What causes excessive water in the regenerant tank of my Puretec SOL40-E3?
    • S
      Samuel JonesAug 27, 2025
      Excessive water in the regenerant tank of your Puretec Water Dispenser can be caused by several factors: incorrect program settings, a plugged injector, a loose or damaged drive cap assembly, a leak from the seal/spacer stack assembly, a restricted or kinked drain line, a plugged backwash flow controller, or a plugged refill flow controller. Solutions include contacting Puretec for assistance regarding program settings, cleaning or replacing the injector, tightening or replacing the drive cap assembly, cleaning or replacing the spacer stack assembly, checking the drain line for restrictions or kinks and addressing them, cleaning or replacing the backwash flow controller, and cleaning or replacing the refill flow controller.
  • A
    abeanAug 29, 2025
    What to do if my Puretec SOL40-E3 valve doesn't regenerate during manual regeneration?
    • J
      Jose WaltersAug 29, 2025
      If your Puretec Water Dispenser valve doesn't regenerate when performing a manual regeneration, it could be due to: no power to the valve (refer to ‘No display/blank screen on valve.’), a broken drive gear or drive cap assembly, or a broken piston rod. To fix this, refer to ‘No display/blank screen on valve.’, replace the drive gear or drive cap assembly, or replace the piston rod.
  • A
    Adrian CharlesAug 31, 2025
    Why Puretec SOL40-E3 valve doesn't regenerate automatically?
    • S
      Sandra SantosAug 31, 2025
      If your Puretec Water Dispenser valve regenerates manually but not automatically, the issue might stem from several causes: the bypass valve being in bypass position or faulty (turn bypass to normal operation or replace bypass), the meter loosely or not connected to PC Board (connect meter into the three pin connector labelled METER on PC Board), a restricted or stalled meter turbine (remove meter and check for rotation or foreign material), incorrect programming (contact Puretec for assistance), a defective meter (replace meter), or a defective PC Board (replace PC Board).
  • C
    cobbbonnieSep 2, 2025
    How to troubleshoot Puretec Water Dispenser error E1?
    • J
      Jodi JacksonSep 2, 2025
      Error code E1 on your Puretec Water Dispenser indicates the control is unable to sense motor movement. This could be due to the motor not being fully inserted, broken or disconnected motor wires, an incorrectly installed PC Board, the board being unable to read the middle reduction gear, missing or damaged reduction gears, or a defective PC Board. To resolve this, disconnect power, ensure the motor is fully engaged, check for broken wires, and ensure the two-pin connector is connected to the PC Board. Also, ensure the PC Board is correctly clipped into the drive bracket, check the foil on the reduction gear for foreign material, replace any missing gears, or replace the defective PC Board. Finally, connect power and perform a 'dry' reset.
  • M
    Morgan MoralesSep 4, 2025
    Why is my Puretec SOL40-E3 Water Dispenser using too much regenerant?
    • A
      aprilfieldsSep 4, 2025
      If your Puretec Water Dispenser control valve is using too much regenerant, it could be due to an incorrect refill setting, an incorrect program setting, or the valve regenerating frequently. Contact Puretec for assistance regarding the refill and program settings. Check for leaking fixtures or if the system is undersized.
  • T
    Teresa TorresSep 6, 2025
    What does Puretec SOL40-E3 Water Dispenser error E2 mean?
    • J
      James SanchezSep 6, 2025
      Error code E2 on your Puretec Water Dispenser means the control valve motor ran too short and was unable to find the next cycle position and stalled. This can be caused by foreign material lodged in the valve, mechanical binding, the main drive gear being too tight, or incorrect voltage being delivered to the valve. You can try cleaning or replacing the piston/spacer stack assembly, checking the piston, spacer stack assembly, drive bracket, and main drive gear interface, loosening the main drive gear, or checking the voltage of the power source. After addressing the potential cause, perform a 'dry' reset.
  • A
    Anthony SellersSep 8, 2025
    What does Puretec SOL40-E3 Water Dispenser error E3 mean?
    • E
      Erica PalmerSep 8, 2025
      Error code E3 on your Puretec Water Dispenser indicates that the control valve motor ran too long and was unable to find the next cycle position. This could be due to motor failure during regeneration, foreign material lodged in the valve, or the drive bracket not being correctly installed. To address this, check the motor connections, clean or replace the piston/spacer stack assembly, or correctly snap the drive bracket in place. After addressing the potential cause, perform a 'dry' reset.

Summary

Installation Record

Before Installation

Professional Installation

Installation requires skilled tradespersons for plumbing and fittings.

Key Installation Warnings

Important safety advice regarding installation procedures and materials.

Specifications

Installation Procedure

Bypass Assembly Connection

Instructions for connecting the bypass assembly to the softener unit.

Main Plumbing Connection

Connect the softener to the main plumbing, adhering to local codes.

Drain and Overflow Setup

Properly connect drain and overflow lines, ensuring air gaps.

Electrical and Programming Start

Initial setup for electrical connections and proceeding to programming section.

Programming

Start-Up

Initial Start-Up Procedure

Step-by-step guide to filling the brine tank and initial system run.

Replenishment of Salt Supply

Bypass Valve Operation

Troubleshooting Guide

Performing a Dry Reset

Steps to perform a 'dry' reset to resolve error codes or display issues.

Troubleshooting: Auto Regen Issues

Troubleshooting automatic regeneration failure while manual works.

Troubleshooting: Hard Water Delivery

Resolving issues of hard or untreated water being supplied.

Troubleshooting: Error E1 - Motor Sensing

Resolving Error E1: motor movement sensing issues.

Troubleshooting: Error E2 - Motor Stall

Resolving Error E2: motor short run and stall.

Troubleshooting: Error E3 - Position Failure

Resolving Error E3: motor long run and position finding failure.

Troubleshooting: Error E4 - Home Timeout

Resolving Error E4: motor long run to home position timeout.