Questions and Answers

  • R
    rburkeAug 20, 2025
    Why is there odour or particles in exhaust air from my Purex iFume 400i PVC, even without machine alerts?
    • W
      whitney10Aug 20, 2025
      The exhaust monitor unit inside your Purex Air Cleaner might have a fault. Begin by inspecting all cables and connections. If the issue continues, contact your supplier.
  • B
    brianhaynesAug 22, 2025
    What to do if Temperature (red) alert appears on Purex iFume 400i PVC?
    • D
      david96Aug 22, 2025
      If a Temperature (red) alert appears, first ensure that nothing is blocking the cooling vents located at the rear of the extractor. Then, check the process temperature and turn off the extractor.
  • S
    Seth ColeAug 25, 2025
    What to do if Temperature (yellow) alert appears on Purex iFume 400i PVC Air Cleaner?
    • O
      Oscar WilliamsAug 25, 2025
      If you receive a Temperature (yellow) alert, check that the cooling vents on the rear of the extractor are free from obstructions. Also, check the process temperature.
  • R
    Ryan ScottAug 26, 2025
    What to do if my Purex Air Cleaner screen is not illuminated?
    • C
      cody78Aug 26, 2025
      If the screen is not illuminated, there could be several reasons: * The power supply might be absent or incorrect. Check all cables and connections, ensuring the power supply matches the machine's requirements. * The circuit breaker might have tripped. Try resetting the breaker on the rear of the machine. * The control PCB inside the machine may have developed a fault. Check all cables and connections first. Then contact your supplier.
  • J
    jamie07Aug 27, 2025
    What to do if Particulate (red) alert appears on Purex Air Cleaner?
    • G
      Gary JohnsonAug 28, 2025
      If a Particulate (red) alert appears on your air cleaner, replace the main filter.
  • U
    uwalkerAug 29, 2025
    What to do if GAS (red) alert appears on Purex iFume 400i PVC Air Cleaner?
    • A
      Andrew DominguezAug 29, 2025
      If a GAS (red) alert appears, you should replace the main filter.
  • A
    Andrew RomeroAug 31, 2025
    Why does my Purex iFume 400i PVC filter have a shorter than expected life?
    • R
      Richard WilliamsAug 31, 2025
      A shorter than expected filter life may be due to: * A problem with the pre-filter. Check the pre-filter for damage or if it is missing. * Changes in the process or its duration, including the use of different materials. Investigate any changes in these factors. If the issue continues, contact your supplier.
  • G
    gmendezSep 2, 2025
    What to do if Particulate (yellow) alert appears on Purex iFume 400i PVC?
    • D
      Dr. Tanner Rodriguez DDSSep 2, 2025
      If you see a Particulate (yellow) alert, order a replacement main filter.
  • O
    oarnoldSep 4, 2025
    What to do if GAS (yellow) alert appears on Purex iFume 400i PVC Air Cleaner?
    • H
      hollowaymartinSep 4, 2025
      If a GAS (yellow) alert appears, order a replacement main filter.
  • W
    walkerjonathonSep 6, 2025
    What to do if the Purex iFume 400i PVC control signal to/from interfaced equipment is incorrect?
    • C
      chavezphilipSep 6, 2025
      If the control signal to or from interfaced equipment is incorrect, and the equipment isn't switching on and there's an alarm, it indicates an electrical problem. Check all cables, connections, and the interfaced equipment.

Summary

Warnings

Installing the Machine

Touchscreen Control System

Touchscreen Display Overview

Introduces the iFume touchscreen interface and its main elements for monitoring and control.

Touchscreen Operation Details

Setting the Machine for the First Time

Setting Maximum Airflow

Procedure to set and calibrate the maximum airflow for optimal efficiency and filter life.

Machine Operation and Airflow Adjustment

Instructions for switching the machine on/off and adjusting airflow rates as needed.

Setting Special Features

Filtration & Changing Filters

Filter Replacement Guidelines

Important notes and precautions before changing filters, and when to order replacements.

Warning and Alarm Signals

Gas, Particulate, and Temperature Alarms

Visual guide to gas, particulate, and temperature warning/alarm indicators on the display.

Troubleshooting

Addressing Operational Issues

Solutions for common problems like odour, airflow, control signal errors, and screen issues.

Purex iFume 400i PVC Specifications

General IconGeneral
BrandPurex
ModeliFume 400i PVC
CategoryAir Cleaner
LanguageEnglish

Related product manuals