Dip2 Dip3 Dip4 Group address number
0 0 0 0: single battery group
1 0 0 1: 1
st
battery group
0 1 0 2: 2
nd
battery group
1 1 0 3: 3
rd
battery group
0 0 1 4: 4
th
battery group
1 0 1 5: 5
th
battery group
0 1 1 6: 6
th
battery group
1 1 1 7: 7
th
battery group
Console
For manufacturer or professional engineer to debug or service.
Pin 2: TXD. Pin3: RXD. Pin1/4: GND
Dry Contact
IN+/GND Input, passive signal. On: turn off battery. Off: normal.
Com/No1 Output1. On: stop charge.
Com/No2 Output2. On: stop discharge.
Com/No3 Output3. On: BMS error.
Output request signal voltage ≤25V
Link Port 0, 1
for communication between multiple parallel batteries.
RS485
9600 or 115200 bps.120Ω recommended. For connection to inverter.
CAN
500 Kbps. 120Ω recommended. For connection to LV-HUB, inverter.