6
2.3 Equipment interface instruction
Power Switch
ON: ready to turn on.
OFF: power off. For storage or shipping.
Start
Turn on: press more than 0.5s to start the battery module
Turn off: press more than 0.5s to turn off the battery.
RUN
Green LED lighting to show the battery running status
Alarm
Red LED flashing to show the battery has alarm; lighting to show the battery is
under protection.
SOC
6 green LEDs to show the battery’s current capacity.
ADD Switch
Dip1: RS485 baud rate 1: 9600; 0: 115200
Dip2~4, reversed.
Console
For manufacturer or professional engineer to debug or service.

Other manuals for Pylontech US3000C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pylontech US3000C and is the answer not in the manual?

Pylontech US3000C Specifications

General IconGeneral
Battery TypeLithium Iron Phosphate (LiFePO4)
Nominal Voltage48V
Capacity74Ah
Discharge Current (Recommended)37A
Discharge Current (Maximum)74A
CommunicationCAN, RS485
Cycle Life6000 Cycles @ 25°C
Operating Temperature-10°C to 50°C
ScalabilityUp to 16 units in parallel
CertificationCE, UN38.3