Matrix 6/816 User Manual
Page 22 RINS545-7
6.1.3 Restoral
Fragment 1
Fragment 2
System Event
Rq
User code after alarm (FTA mode entered)
Rw
Bell time expired
Re
Power supply applied (restored) to panel from de-energized state
.R pw
Auxiliary fuse restoral
.R pe
Battery missing restoral (DC voltage on terminals +BAT- restored)
.R pr
Battery low voltage restoral (DC voltage on terminals +BAT- > 11.2V)
.R pt
Mains fail restore
.R py
Telephone line fail restore
.R pi
Successful transmission to central station (Kiss Off signal received)
.R po
Battery cut-off restoral (reset pressed and DC voltage on +BAT-
> 10.5V)
(Matrix 816 Only)
6.1.4 System Faults
Fragment 1
Fragment 2
System Event
. pw
Auxiliary fuse fail
. pe
Battery missing (DC voltage missing on terminals +BAT-)
. pr
Battery low voltage (DC voltage on terminals +BAT- < 11.2V)
. pt
Mains fail
. py
Telephone line fail
. pi
Transmission to central station failed (Kiss Off signal not received)
. po
Battery cut-off (DC voltage on +BAT- < 10.5V) (Matrix 816 Only)
6.1.5 System Events
Fragment 1
Fragment 2
System Event
Eq
Engineer mode entered
Ep
Engineer mode exited
¥ pq
Walk test mode entered
¥ pw
Walk test mode exited
¥ pr
NVM Reset
DT pq
Time and date changed by User no. 1 or from Engineer mode
nO
Patrol zone opened
nO
Patrol zone closed