82
4
• Dehumidifier does not dry air as intended.
Problem Possible Causes Solution
Bad dehumidifying
performance
Check whether there is
any obstacle around the
unit.
Make sure there is no
curtain, shutter or
furniture that blocks the
dehumidifier.
Air filter is dusty and
blocked.
Clean the filter.
Doors and windows are
left open.
Make sure all doors
and windows and other
opening to the outside
have been closed.
Room temperature is too
low.
Warm temperature is good
for dehumidification.
Low temperature will
reduce unit's working
effect. This unit should be
working in a place where
temperature is above 5ºC.
MALFUNCTION CODES
• Unit's Malfunction Codes.
No.
Malfunction
Name
Display
Code
Unit's Condition Possible Causes
Display
Window
1
Ambient
Temperature
Sensor
Malfunction
F1
Compressor and fan
motor stop. This
button is invalid.
Ambient temperature
sensor is loosen or is
poorly connected with the
terminal of display board.
Some element of display
board may have been put
upside down and cause
short circuit.
Ambient temperature
sensor is damaged (Please
refer to Checking Table
for Temperature Sensor
Resistance).
Display board is damaged.
2
Tube
Temperature
Sensor
Malfunction
F2
Compressor and fan
motor stop. This
button is invalid.
Temperature sensor on the
evaporator is loosen or is
poorly connected with the
terminal of display board.
Some element of display
board may have been put
upside down and cause
short circuit.
Temperature sensor
on the evaporator is
damaged(Please refer
to Checking Table for
Temperature Sensor
Resistance).
• Display board is damaged.

Table of Contents