USEFUL INFORMATION ABOUT HOW THE HEATING MODE OPERATES
When the incoming water temperature is less than or equal to the required temperature (setpoint
temperature) -X°C, the heat pump will switch to heating mode. The compressor will stop when the
temperature of the incoming water is greater than or equal to the required temperature (setpoint
temperature).
Indicators for adjustment range X and Y
X : adjustable parameter from 1° to 15°C, default setting is 3°C. (Parameter N°6)
STATUS VALUES AND ADVANCED SETTINGS
WARNING
This operation is used to assist servicing and future repairs.
The default settings should only be modified by an experienced professional person.
The system’s settings can be checked and adjusted via the remote control by following these steps
1. Keep pressing
until you enter the settings verification mode.
2. Press
and for see the parameters.
3. Press
to select the setting to be modified.
Note, some settings cannot be modified. Consult the settings table for further information.
4. Press
and to adjust the setting value.
5. Press
to set the new value.
6. Press to
return to the main screen.
4
Parameter D
Value 40
Q_man_SPHP 130 ('21) V6.indd 44Q_man_SPHP 130 ('21) V6.indd 44 21-12-20 14:1521-12-20 14:15

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Qlima SPHP 130 and is the answer not in the manual?

Qlima SPHP 130 Specifications

General IconGeneral
Best uses-
Control typeButtons
Product typeElectric pool heater
Product colorBlue
Easy to installYes
Buttons quantity4
Pool capacity (max)16000 L
Pool capacity (min)- L
Units of measurement°C
Maximum heating capacity2.8 °C/h
Minimum pumping capacity2 m³/h
Temperature measurement range15 - 40 °C
Coefficient of performance (COP)4.83
International Protection (IP) codeIPX4
Operating temperature (T-T)8 - 43 °C
Motor power580 W
Input voltage220 - 240 V
Input frequency50 Hz
Weight and Dimensions IconWeight and Dimensions
Depth400 mm
Width385 mm
Height280 mm
Weight18000 g

Related product manuals