EasyManua.ls Logo

Qlogic QL45212 - Page 74

Qlogic QL45212
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6–Configuring RoCE
Configuring RoCE on the Adapter for Windows Server
56 BC0154503-00 C
4. Verify that RoCE is enabled on the adapter using Windows PowerShell
®
.
The Get-NetAdapterRdma command lists the adapters that support
RDMA—both ports are enabled.
PS C:\Users\Administrator> Get-NetAdapterRdma
Name InterfaceDescription Enabled
----- -------------------- -------
SLOT 4 3 Port 1 QLogic FastLinQ QL45212... True
SLOT 4 3 Port 2 QLogic FastLinQ QL45212... True
5. Verify that RoCE is enabled on the host operating system using PowerShell.
The Get-NetOffloadGlobalSetting command shows NetworkDirect is
enabled.
PS C:\Users\Administrators> Get-NetOffloadGlobalSetting
ReceiveSideScaling : Enabled
ReceiveSegmentCoalescing : Enabled
Chimney : Disabled
TaskOffload : Enabled
NetworkDirect : Enabled
NetworkDirectAcrossIPSubnets : Blocked
PacketCoalescingFilter : Disabled
6. Connect a server message block (SMB) drive, run RoCE traffic, and verify
the results.
a. Map an SMB drive, and then run RoCE traffic.
b. Launch Performance Monitor.

Table of Contents