User wavetables can be created using the Synthesis Technologies WaveEdit software.
Each .WAV file will be loaded as 8 banks of 8 waveforms.
A config setting in the config.txt file can be changed to map all 64 waveforms to the waveform
knob, 8 WAV files can be loaded this way.
No naming convention necessary, but the chord will only load the first .wav file it finds.
Calibration
The module arrives calibrated using precise test equipment, however there are use cases
where a different input standard is desired.
To enter the calibration mode make sure that no CV inputs are inserted into the module, and
hold the Triad button for 3 seconds.
The Major LED will become illuminated Red.
When Maj is RED use V/oct jack.
When Min is RED use Lead jack.
When Dom is RED use Voicing jack.
When Dim is RED use Quality jack.
The process is repeated for each of the 1V/octave inputs.
For 1V/Octave:
Insert +1V into the V/Oct jack, and press Triad. The Asterick LED will illumintate.
Increase voltage to +3V, and press Triad. The next LED will illumintate.
Remove voltage from V/Oct, insert +1V into next jack, and repeat.
For other voltage standards, use the voltage for 1 octave above the root, and 3 octaves
above the root instead of +1V and +3V.
For example, to calibrate this to be compatible with Buchla modules use +1.2V and +3.6V
17

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Qu-Bit Electronix Chord v2 and is the answer not in the manual?

Qu-Bit Electronix Chord v2 Specifications

General IconGeneral
BrandQu-Bit Electronix
ModelChord v2
CategoryMusic Equipment
LanguageEnglish