Jumper Settings
To ensure correct system configuration, the following section describes how to set
the jumpers to enable/disable or change functions. For jumper descriptions, please
refer to the table below.
Table 2 Jumper List
Label Function
JP1 Power Mode Selection
JP2 Clear CMOS Selection
JP3 Backlight & Panel Power Selection
JP4 Clear ME RTC Registers
JP5 Backlight Enable Selection
Table 3 JP1 Power Mode Selection
Jumper Status
Open ATX Mode (Default)
Short AT Mode
Table 4 JP2 Clear CMOS Selection
Jumper Status
Open Normal Operation (Default)
Short Clear CMOS
Table 5 JP3 Backlight & Panel Power Selection
Jumper Setting Status
1
1-3 Backlight Power = +12V (Default)
3-5 Backlight Power = +5V
2
2-4 Panel Power = +3.3V (Default)
4-6 Panel Power = +5V
Table 6 JP4 Clear ME RTC Registers
Jumper Status
Open Normal Operation (Default)
Short Clear ME RTC Registers
Table 7 JP5 Backlight Enable Selection
Jumper Status
1-2 Active High (Default)
2-3 Active Low