Inspecting VoIP Traffic
Quantum Spark 1500, 1600 and 1800 Appliance Series R80.20.40 Locally Managed Administration Guide | 183
n
Phones are connected via VPN Site to Site.
n
Phones are connected by VPN Remote Access.
n
Phones are configured with public IP.
The network objects appear in a table, with a Group name.
Click New to add an item.
Select an item and click Remove to delete it.
7. Click the SIP Service heading to expand the section.
Select the SIP UDP/TCP ports, which by default are 5060.
All phones should be configured to use the configured ports.
Click New to add a new SIP service.
Click Remove to delete a service.
After you apply these settings, rules are automatically created in the Firewall Access Policy page for
Outgoing access to the Internet and Incoming, Internal and VPN traffic.
Notes:
n
For an on-premise configuration without PBX, the destination should be the IP_Phones object.
n
If you allow access to the PBX portal, another rule is created:
Source Destination
Application /
Service
Action Log Comment
Any PBX-Server HTTP/S Accept None Generated rule: SIP
VOIP
Forwarding rules are automatically created in the Access Policy > NAT Rules page.
Note - For external phones with remote access, the Office Object is automatically created in the Network
Objects section and the " set back connection" setting is set to "true".
Follow these configuration procedures to allow SIP traffic to pass through the gateway when:
n
The SIP server is located on external networks. For more advanced topologies, refer to sk113573.
n
The gateway's NAT configuration is set to its default settings (with internal networks hidden behind its
external IP address).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quantum CHECK POINT SPARK 1800 Series and is the answer not in the manual?

Quantum CHECK POINT SPARK 1800 Series Specifications

General IconGeneral
BrandQuantum
ModelCHECK POINT SPARK 1800 Series
CategoryNetwork Hardware
LanguageEnglish

Related product manuals