The
Buffer
Full
Ratio
applies
when
the
drive
is
reading
from
the
disk.
The
drive
fills
buffer
memory
while
the
SCSI
bus
is
emptying
it.
If
the
drive
must
seek
for
more
data,
the
SCSI
bus
may
empty
the
buffer,
at
which
time
the
drive
dis-
connects.
Now
assume
the
drive
is
much
faster
than
the
SCSI
bus:
then
the
drive
should
reconnect
as
soon
as
there
is
anything
in
the
buffer,
and
the
Buffer
Full
Ratio
should
be
set
to
00.
Conversely,
if
the
SCSI
bus
is
much
faster
than
the
drive,
the
drive
shouldn't
reconnect
until
the
buffer
is
full
(Buffer
Full
Ratio
=
FF).
In
many
situations,
the
host
will
request
a
transfer
of
a
specific
size;
near
optimum
bus
utilization
is
obtained
by
setting
the
Buffer
Full
Ratio
so
the
drive
has
filled
the
buffer
with
that
much
data
before
reconnecting:
if
the
host
asks
for
4
KBytes,
wait
for
the
drive
to
transfer
4
KBytes
to
the
buffer
before
reconnecting.
This
strategy
avoids
excessive
disconnect/reconnect
SCSI
bus
overhead.
Buffer
Empty
Ratio
applies
when
the
drive
is
writing,
and
is
the
mirror
image
of
the
situation
when
the
drive
is
reading.
The
SCSI
bus
fills
buffer
memory
while
the
drive
is
emptying
it.
If
the
drive
must
seek,
the
SCSI
bus
may
fill
the
buf-
fer,
at
which
time
the
drive
disconnects.
Now
assume
that
the
SCSI
bus
is
much
faster
than
the
drive:
then
the
drive
should
reconnect
even
if
the
buffer
is
nearly
empty
(Buffer
Empty
Ratio
=
00).
Conversely,
if
the
drive
is
much
faster
than
the
SCSI
bus,
the
drive
should
reconnect
when
the
buf-
fer
is
full
(Buffer
Empty
Ratio
=
FF).
If
the
host
transfers
data
in
known
size
blocks,
near
opti-
mum
bus
utilization
is
obtained
by
setting
the
Buffer
Empty
Ratio
so
the
buffer
is
filled
with
that
much
data
before
reconnecting.
3.
When
transferring
data,
use
the
maximum
number
of
blocks
within
a
single
read
or
write
command.
Since
each
indivi-
dual
command
has
an
overhead
associated
with
it,
the
more
individual
commands
used,
the
lower
the
data
throughput.
If
a
file
consists
of
several
blocks
located
in
sequentially
increasing
LBAs
(logical
block
addresses),
use
one
command
to
read
all
of
the
blocks,
instead
of
many
commands
of
one
block
reads
or
writes.
Also,
adjust
the
block
size
with
the
MODE
SELECT
command
to
allow
up
to
4
sectors
to
be
read
with
a
single
block
command.
Since
the
Q250/Q280
drives
are
hard
sectored
and
have
a
fixed
interleave
of
1:1,
optimizing
the
block
size
and
number
of
blocks
per
read
can
have
a
dramatic
impact
on
overall
performance.
4-4