EasyManuals Logo

QUBINO Smart meter User Manual

QUBINO Smart meter
51 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
EN.
10
2.2. Installation examples for the Smart Meter - used for measuring energy
consumption and for controlling* electrical devices
(*with additional external contactors - IKA/BICOM. IKA and BICOM are sold separately - for
more info, please see Qubino catalogue. Product ordering codes (model numbers): IKA232-
20/230V: 030 046 833 000; BICOM432-40-WM1: 30.074.038)
Remotely control and measure the
power consumption of one electrical
device (for example: water heater)
with external relay BICOM432-40-WM1
Remotely control and measure the
power consumption of one electrical
device (for example: oven) with the
external relay IKA232-20/230V
Remotely measure the power
consumption of the whole house and
control two groups electrical devices
with BICOM432-40-WM1 and IKA232-
20/230V

Other manuals for QUBINO Smart meter

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the QUBINO Smart meter and is the answer not in the manual?

QUBINO Smart meter Specifications

General IconGeneral
Communication ProtocolZ-Wave
Weight150 g
Rated Current65 A
AccuracyClass 1
Frequency50/60 Hz
Radio ProtocolZ-Wave
Power Consumption< 1 W
Z-Wave Frequency868.42 MHz (EU)
RangeUp to 30 m indoors
Operating Temperature-10°C to +40°C