EasyManuals Logo

QUBINO Smart meter User Manual

QUBINO Smart meter
51 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #48 background imageLoading...
Page #48 background image
EN.
48
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2
* Command classes on endpoints are supported securely only if the device is added to a Z-Wave
network as secure.
NOTE:
Endpoints are shown/hidden by Parameter No. 100
The device will be turned ON or OFF after receiving the BASIC_SET command.
To be turned ON: [Command Class Basic, Basic Set, Basic Value = 0x01~0x63; FF]
To be turned OFF: [Command Class Basic, Basic Set, Basic Value = 0x00]
BASIC SET/GET on root device is mapped to basic set/get of both endpoints.
COMMAND_CLASS_METER
Default values:
o Rate Type = 1 (Import)
Scale = 0 (kWh)
This device can be included and operated in any Z-Wave network with other Z-Wave certified
devices from any other manufacturers. All constantly powered nodes in the same network will
act as repeaters regardless of the vendor in order to increase reliability of the network.

Other manuals for QUBINO Smart meter

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the QUBINO Smart meter and is the answer not in the manual?

QUBINO Smart meter Specifications

General IconGeneral
Communication ProtocolZ-Wave
Weight150 g
Rated Current65 A
AccuracyClass 1
Frequency50/60 Hz
Radio ProtocolZ-Wave
Power Consumption< 1 W
Z-Wave Frequency868.42 MHz (EU)
RangeUp to 30 m indoors
Operating Temperature-10°C to +40°C