Quest DEH 3000R Installation, Operation and Maintenance Instructions
14
www.QuestProtect.com
sales@questprotect.com
Whenyouhavenishedprogrammingyourschedule(eitherthe7-dayversionortheweekday/weekendsplit
version),usethedown“RH”buttontohighlighttheEXIToptionandthenpressPROGRAM ENTER”toselectit.
RunningtheVentilationProgram
PressandholdthePROGRAM ENTER”buttonuntilthe“PROGRAMscreenappears.
UsethedownRHbuttontohighlightRUN PROGRAM:
ThenpressPROGRAMENTERtoselectit.Thedisplaywillappearasfollows:
3.9 Temperature Cutout Programming
Dehumidiersproduceheatwhendehumidifyinganddependinguponoutsideconditions,theventilation
functionmayalsointroducewarmair.Someconditionsmayintroduceenoughheattodrivetemperaturesup.
TheQuestDEH3000RtemperaturecutoutfeaturedisablesallQuestoperationsiftemperaturesreachthecutout
setpoint.
Inmostinstallationsthisfeaturewillnotneedtobeused(thecutoutisfactorysetto99°F).Ifalowertemperature
cutoutisdesired,programthesetpointbypressingandholdingthePROGRAMENTERbuttonuntilthe
PROGRAM”screenappears.Presstheup/down“RH”buttonsuntilTEMPCUTOUThighlighted.Thenpress
the“PROGRAMENTERbuttonagaintoselectit.NowusetheRHuporRHdownbuttonstoadjustthe
setpoint.PressPROGRAMENTERtoreturntothehomescreen.