31
QVM 9
Series
Apply soapy water on the gas piping, shut-off
valve and the gas connections to check for leaks.
Check for any rust and clogs in the flue duct.
Check if the “Check Lamp” is “ON” (FR-5
thermostat).
IfCheck Lamp is lit, note the error code shown
to assist in repair and service of the water heater.
If the water heater exterior is dirty, disconnect
power to the water heater, wipe the water heater
with a wet cloth soaked with mild detergent and
remove moisture with dry cloth.
CAUTION
DO NOT USE A NYLON BRUSH OR OTHER STATIC
CREATING MATERIAL TO CLEAN DUST AND
CARBON DEPOSITS FROM HEATING SURFACES
AND VENT.
SUCH DEPOSITS ARE FLAMMABLE AND MAY BE
IGNITED BY STATIC ELECTRICITY. USE A METAL
BRUSH TO MINIMIZE THE DANGER OF EXPLOSION.
DO NOT ATTEMPT TO SERVICE YOUR APPLIANCE
YOURSELF.
Routine Maintenance
For failure-free, safe and economical use, routinely check and clean the gas water heater.
Checks and maintenance should be done after the gas valve has been closed and the
water heater has cooled down fully.
Other matters not specifically covered in the following checks and maintenance refer to the
trained technician.
Routine Checks
Call a Quietside Coporation
authorized service
technician
Maintenance and Cleanin