EasyManua.ls Logo

Quietside QVM 9-090W1-NG User Manual

Quietside QVM 9-090W1-NG
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
FIRST YEAR
Limited Warranty for Condensing Gas Water Heater
(All Residential Commercial Water Heater)
(Includes Space Heating Domestic Water ‘Combo’ Heating Applications)
Quietside Corporation warrants that its combo water heater are free from
defects in materials and workmanship for one year from the date of
installation. If any parts are found to be defective in manufacture,
Quietside Corporation will provide replacement of such defective parts.
SECOND THROUGH THE TENTH YEAR
Limited Warranty for Primary Heat Exchangers
(Residential Water Heater Only)
(Space Heating Applications Only)
Quietside Corporation warrants that the copper tube (primary) heat
exchanger of its residential condensing gas model water heater is free
from defects in material and workmanship from the date of installation
for the second through the tenth year to the original purchaser only. If
during such time period, any part of the copper tube heat exchanger is
found to be defective, Quietside Corporation will provide replacement for
the original heat exchanger.
ELEVENTH YEAR AND BEYOND
Limited Warranty for Primary Heat Exchangers
(Residential Water Heater Only)
(Space Heating Applications Only)
Quietside Corporation warrants, to the original purchaser only, that the
copper tube (primary) heat exchanger of its residential condensing gas
model water heater is free from defects in material and workmanship for
the eleventh year and beyond from the date of installation. If during such
time period, any portion of the copper water tubing is found to be
defective, Quietside Corporation will provide replacement for the original
copper tube heat exchanger upon the payment of a proportionate charge
based on the time the water heater has been in service. The proportionate
charge will be equal to the appropriate percentage of the list price of such
copper tube heat exchanger at the time the warranty claim is made, and
will be determined as follows :
11
th
Year 10%, 12
th
Year 15%, 13
th
Year – 18%
14
4h
Year 20%, 15
th
Year 25%, 16
th
Year – 30%
17
th
Year 35%, 18
th
Year 40%, 19
th
Year – 45%
20
th
Year 50%, 21
th
Year 55%, 22
th
Year – 60%
23
th
Year 65%, 24
th
Year – 70%,
25
th
Year and beyond – 75%
*NOTE : If the heat exchanger model involved is no longer
available due to product obsolescence or redesign, the value
used to establish the retail price will be the publish price as
shown in the Quietside repair parts booklet where the heat
exchanger last appeared or the current retail price of the then
nearest equivalent heat exchanger.
SPECIAL FIVE YEAR WARRANTY
Limited Warranty for Flat Plate Heat Exchangers
(Domestic Hot Water Heat Exchangers – Residential Use Only)
Quietside Corporation warrants that the stainless steel, flat plate heat
exchanger (used for the production of domestic hot water ) is free from
defects in material and workmanship for five years from the date of
installation. Any coagulation or blockage of the normal water flow
through the heat exchanger, due to trapped sediment, heavy calcification,
lime deposits minerals and or other waterborne buildup in the plate heat
exchanger, or corrosion due to chemical anti-freeze additive is not
considered defects in workmanship and therefore any malfunction or
damage to other parts or components resulting from these buildups in
the plate heat exchanger is not covered under the terms of this warranty.
This Warranty Does Not Cover :
1. Installations by other than qualified heating contractors.
2. Installations of equipment for other purposes than those intended by
the instructions supplied with this equipment.
3. Installations of equipment for purposes other than residential space
heating and domestic hot water production.
4. Any product which is improperly installed or moved from its original
place of installation.
5. Any product, which has been repaired or replaced with other than
Quietside factory parts.
6. Any product modified in any way, misused or damaged or which as
been used contrary to warrantors written instructions.
7. Any damage resulting from use of anti-freeze solutions added to the
heating water or combustion air drawn from interior spaces.
8. Any damage to the product caused by failure to maintain the unit properly,
improper voltage, improper gas pressure, improper water pressure, flood,
fire, lightning, or Acts of God.
9. Nicks, scratches or discoloration of decorative finishes.
10. Installation, plumbing , gas piping and wiring not integral to the
product.
11. This warranty does not covered and expenses related to the removal
or re-installation process. The homeowner will be responsible for the
cost of removing and re-installing the alleged defective part or its
replacement and all labor and material connected therewith, and
transportation to and from Quietside Corporation.
12. The warranty cannot be considered as a guarantee of workmanship
of an installer connected with the installation of the condensing water
heater, or as imposing a liability of any nature for unsatisfactory
performance as a result of faulty workmanship in the installation,
which liability is expressly disclaimed.
Exclusion of Incidental and Consequential Damages
Quietside Corporation will not pay in contract or in tort, consequential or
incidental damages under this warranty, both of which are specifically excluded.
This means we shall not be responsible for any loss, expense or damage caused
by any defect in the Water Heater, other than the water heater itself.
The maximum liability of Quietside Corporation in connection with this limited
warranty shall not in any case exceed price of the part claimed to be defective, or
price of the water heater if the entire water heater is claimed to be defective.
“Incidental” damages include expenses of inspection, obtaining substitute
goods, transportation, etc.
“Consequential” damages include injury to persons or property resulting
from a breach of warranty.
Owners Responsibilities
This Warranty is issued to the original purchaser only. This product must
be used and cared for in accordance with the instruction manual. You are
responsible for required periodic maintenance or service such as
lubrication, cleaning the strainer and cleaning the components. See your
instruction manual for details. You must be able to verify the installation
date of the product against which you make any warranty claim. The
original bill of sale, installers invoice or other similar document is
required to verify warranty. If you cannot show evidence of the actual
date of installation, warranty coverage will be considered to start on the
date the product is shipped from our distributor.
The attached warranty card must be filled out completely and returned to
Quietside Corporation. Failure to do so will prevent or delay our being
able to contact you (or the person residing at this address) in case of a
recall or important product safety alert.
Your warranty information will be held strictly confidential.
QVM 9 SERIES CONDENSING GAS WATER HEATER

Questions and Answers:

Quietside QVM 9-090W1-NG Specifications

General IconGeneral
BrandQuietside
ModelQVM 9-090W1-NG
CategoryWater Heater
LanguageEnglish

Summary

LIMITED WARRANTY

SECOND THROUGH THE TENTH YEAR WARRANTY

Warranty for primary heat exchangers for the second through tenth year.

ELEVENTH YEAR AND BEYOND WARRANTY

Warranty for primary heat exchangers from the eleventh year onwards.

SPECIAL FIVE YEAR WARRANTY

Warranty for domestic hot water flat plate heat exchangers.

THIS WARRANTY DOES NOT COVER

EXCLUSION OF INCIDENTAL AND CONSEQUENTIAL DAMAGES

OWNER'S RESPONSIBILITIES

IDENTIFYING THE COMPONENTS

SAFETY ISSUES

FOR YOUR SAFETY READ BEFORE OPERATING

Essential safety instructions to read before operating the appliance.

WHAT TO DO IF YOU SMELL GAS !

Steps to follow in case of a gas leak detection.

OPERATING INSTRUCTION

Step-by-step guide for operating the unit.

TO TURN OFF GAS TO APPLIANCE

Procedure to safely shut off the gas supply to the appliance.

SAFETY ISSUES

1. IGNITION FAILURE

Safety related to ignition system failure.

2. FLAME DETECTION

Safety related to flame detection failure.

6. OVERHEAT PROTECTION

Safety feature to prevent overheating.

7. LOW WATER-LEVEL SAFETY

Safety mechanism for low water level.

SAFETY ISSUES

USE ONLY THE GAS TYPE INDICATED ON THE RATING PLATE

Importance of using the correct gas type as specified.

PROPANE CONVERSION WARNING

Warning about propane conversion requiring a qualified technician.

WINTER FREEZE PREVENTION

Precaution for preventing freezing in winter.

UNINTENDED USE WARNING

Warning against using the unit for unintended purposes.

SAFETY ISSUES

RISK OF SCALDS

Information on burn times at different water temperatures.

SCALDS FIRST AID

First aid procedures for scald burns.

ADVANTAGES OF QVM 9 HYDRONIC HEATING SYSTEM

HOW DOES IT WORK?

Explanation of the heating system's operational modes.

DOMESTIC HOT WATER PRIORITY

How domestic hot water takes priority over space heating.

THE SEALED-COMBUSTION PROCESS

Description of the unit's sealed combustion process.

ADVANTAGES OF QVM 9 HYDRONIC HEATING SYSTEM

QUIETSIDE QVM PRODUCT FEATURES AND FUNCTION

Overview of key features and functions of the QVM 9 unit.

ADVANTAGES OF QVM 9 HYDRONIC HEATING SYSTEM

SAFETY PROTECTION

Detailed safety mechanisms and protections implemented in the unit.

PROPER USE

BEFORE USING

Initial checks and preparations before operating the unit.

NOTES FOR IGNITION

Important notes regarding the unit's ignition process.

WHEN THE WATER HEATER IS NOT USED FOR A PROLONGED PERIOD

Procedures for storing the unit during long periods of non-use.

INSTALLATION

SHIPPING FROM FACTORY

Information on how the unit is shipped from the factory.

CHOOSING THE BEST LOCATION

Guidelines for selecting an appropriate installation location.

INSTALLATION

METHODS OF INSTALLATION

General methods and requirements for installing the unit securely.

CHECK THE TYPE OF GAS

Procedure to verify the type of gas being supplied.

INSTALLATION OF THE FLUE

Instructions for installing the exhaust flue system.

INSTALLATION

THERMOSTATIC MIXING VALVE REQUIREMENT

Requirement and function of a thermostatic mixing valve.

SCHEMATIC OF PIPING INSTALLATION

Diagram illustrating the piping connections for the unit.

INSTALLATION

PRECAUTIONS FOR INSTALLATION

Important precautions to observe during installation.

INSTALLATION

WARNING (FLAMMABLE VAPORS)

Warnings about flammable vapors and installation location.

WARNING (CARPETED FLOOR)

Warning against installing the unit directly on a carpeted floor.

GAS PIPING CONNECTIONS

APPROVED GAS PIPING MATERIALS

Approved materials for gas piping connections.

PROPANE GAS PRECAUTIONS

Specific precautions when using propane gas.

GAS SUPPLY PRESSURE LIMITATIONS

Warning about gas supply pressure limitations.

GAS PIPING CONNECTIONS

STANDARD GAS PIPING

Standard procedures and requirements for gas piping.

TRIAL OPERATION QUICK-FILL

Steps for the quick-fill trial operation procedure.

INSTALLATION OF THE FLUE

PVC VENTING METHOD

Method for venting using PVC pipes.

INSTALLATION OF THE FLUE

FLUE PIPES USED FOR SCF-9 MODELS

Specifics for flue pipes used with SCF-9 models.

RECOMMENDED INSTALLATION

Recommended installation practices for flue and air supply.

INSTALLATION OF THE FLUE

SCHEMATIC OF SCF-9 INSTALLATION

Diagram illustrating the SCF-9 flue installation.

DRAINING CONDENSED WATER

IMPORTANT!!! (SIPHON RESERVOIR)

Critical note about filling the siphon reservoir with water.

ABOUT THE FR-5 THERMOSTAT

ADVANTAGES OF THE MODEL FR-5 THERMOSTAT

Benefits and features of the FR-5 thermostat.

[THE AIR TEMPERATURE MODE]

Explanation of the thermostat's air temperature sensing mode.

[THE WATER TEMPERATURE MODE]

Explanation of the thermostat's water temperature sensing mode.

[ENERGY SAVING MODE]

Description of the energy-saving mode for the thermostat.

INSTALLATION OF THE THERMOSTAT

CHOOSING THE BEST LOCATION

Guidelines for selecting the optimal location for thermostat installation.

INSTALLATION

Step-by-step instructions for physically installing the thermostat.

USING THE THERMOSTAT, FR-5

THERMOSTAT MODEL FR-5

Overview of the FR-5 thermostat's components and indicators.

ROOM TEMPERATURE CONTROL

How to set the desired room temperature.

HEATING WATER TEMPERATURE BUTTON & LAMP & DIAL

Controls for setting heating water temperature.

ENERGY SAVING MODE

Details on using the energy-saving mode.

USING THE THERMOSTAT, FR-5

WHEN THE HEATING WATER TEMPERATURE MODE IS SELECTED

Steps for operating in heating water temperature mode.

UNOCCUPIED (ENERGY SAVING MODE)

Steps for activating the unoccupied energy saving mode.

USING THE THERMOSTAT, FR-5

WHEN THE HEATING IS CONTROLLED BY THE ROOM TEMPERATURE

How to control heating based on room temperature.

USING THE THERMOSTAT, FR-5

OPERATING FOR DOMESTIC HOT WATER MODE DURING SUMMER SEASON

How to operate in domestic hot water mode during summer.

TABLE- ERROR CODES

List of error codes and their corresponding problems.

TEST OPERATION AND CHECKS

CHECKUP AFTER INSTALLATION

Checks to perform after the unit has been installed.

CHECKING FOR GAS AND WATER LEAKS

Procedures for checking for gas and water leaks.

CHECKS BEFORE TRIAL OPERATION

Checks to perform before the initial trial operation.

TEST OPERATION AND CHECKS

TRIAL OPERATION

Step-by-step guide for the trial operation of the unit.

TEST OPERATION AND CHECKS

CHECKING OPERATION OF THE UNIT

How to check if the unit is operating correctly.

ROUTINE MAINTENANCE

ROUTINE CHECKS

Regular checks to perform on the unit.

MAINTENANCE AND CLEANING

Procedures for cleaning and maintaining the unit.

ROUTINE MAINTENANCE

ROUTINE CHECKLIST

A checklist of routine maintenance items and measures.

BRAZED PLATE HEAT EXCHANGER - SERVICE AND MAINTENANCE TIPS

<DOMESTIC HOTWATER HEAT EXCHANGER>

Service and maintenance for the domestic hot water heat exchanger.

WATER QUALITY

Recommended water quality for heat exchanger longevity.

WATER STRAINER

Importance and installation of a water strainer.

CONNECTIONS

Procedures for connecting the heat exchanger.

DIMENSIONAL DRAWING OF THE UNIT

SAFETY VALVE

Function of the safety valve and draining procedure.

STRAINER

Function of the strainer and cleaning procedure.

TROUBLESHOOTING - ERROR CODES

ERROR CODE

Table listing error codes, their causes, and troubleshooting steps.

TROUBLESHOOTING - ERROR CODES

DIP S/W SETTING ON MAIN CONTROLLER

DIP switch settings for various operating modes.

WIRING CONNECTORS

Diagrams of wiring connectors and their pin assignments.

WIRING DIAGRAM

QVM 9 SERIES WIRING DIAGRAM

Detailed wiring diagram for the QVM 9 series.

LEGEND

Color code legend for wiring diagram.

TROUBLESHOOTING

SYMPTOMS

Common symptoms indicating unit malfunction.

CAUSES

Potential causes for the observed symptoms.

TROUBLESHOOTING

Recommended troubleshooting steps for various issues.

EXPLODED VIEWS

MODELS : QVM9-090W1-NG / 125W1-NG / 150W1-NG

Exploded view diagrams for different QVM9 models.

PARTS LIST

MODELS : QVM9-090/125/150W1-NG

Comprehensive list of parts for QVM9 models.

PARTS LIST

MODELS : QVM9-090/125/150W1-NG

Continuation of the parts list with part codes and remarks.

SPECIFICATIONS

QUIETSIDE WATER HEATER

Specifications for the Quietside water heater models.

DOMESTIC HOT WATER

Specifications related to domestic hot water performance.

OTHER DATA

Additional technical data and specifications.

Related product manuals