Section V - Preparing for Maintenance or Service
82 Quincy Compressor-QSI
®
To maintain warranty and to insure the compressor operates correctly and safely you must use gen-
Compressor parts, or perform recommended scheduled maintenance, will void warranty and result
discharge, remove all electrical power from the equipment per OSHA requirements for lock-out
If the branch circuit protection is provided using a fused disconnect to supply power to the com-
that the connections at the branch circuit protection device are tight and the wire insulation is
-
Inspect all tubing in the compressor package for possible leaks, or normal aging and replace with
-
tion and be sure to mark sample with customer name, compressor model, compressor serial num-
Replace all consumables at recommended service intervals or sooner if operating conditions war-
Normal service intervals
Air Filter 2000 Hours
Oil/Fluid Filter 1000 Hours
Separator 4000 Hours
Poor maintenance or the use of non-genuine Quincy Compressor parts will cause equipment failure
Important Maintenance Requirements