8 Unscrew the cap screws with the supplied allen key, remove the tank cover and disconnect the
wire plugs.
9 Remove the insulation. Start with the centre piece.
10 Use the pipe wrench to unscrew the eight nuts and remove the internals.
11 Remove the filter by pulling the metal clips apart.
- Empty the tank and discard loose scale from it. Please note: There is still water left in the tank.
Use the supplied Scotchbrite with water to lightly remove the bulk of the scale from the tank,
internals and filter.
8
10
9
11
click!
Please note
Do not use any descaling agents or
abbrasive pads when removing scale from
the tank.