5
Fusion, Flex and
Tap Nordic single tap Nordic mixer tap Front
Tap hole 32 mm 35 mm 35 mm
Recommended temp. mixing water Not Applicable 60 °C 60 °C
Tap base ring available yes yes no
Tank PRO3 COMBI+
Voltage 230 V 230 V
Power* 1600 W 2200 W
Content 3 litres 7 litres
Heating-up time* 10 minutes 20 minutes
Standby power consumption* 10 W 10 W
Tank height 47 cm 49 cm
Required working height 55 cm 57 cm
Tank diameter 15 cm 20 cm
Minimum water supply pressure 200 kPa (2 bar) 200 kPa (2 bar)
Maximum water supply pressure 600 kPa (6 bar) 600 kPa (6 bar)
Maximum working pressure 800 kPa (8 bar) 800 kPa (8 bar)
Mounting bracket / bracket available yes yes
Stop tap electric
HiTAC
®
water lter High Temperature Activated Carbon
Safety - maximum temperature
- pressure relief valve 800 kPa (8 bar)
Energy label of the Quooker COMBI+
Stated capacity prole XXS
Energy eciency class for water heating A
Energy eciency of water heating 36%
Annual consumption* 511 kWh/year
Hot water temperature setting of water heater 40 - 60 °C
*These values are averages.
According to European laws and regulations regarding the energy eciency of domestic hot water appliances,
the COMBI+ tank carries an A-label. PRO3 tanks only supply boiling water. The EU has not established
an energy label guideline for boiling water tanks. However, these tanks are just as economical.