Installation and Owner’s Manual – Radiant
®
Heat Pump
13
H4121 025960 Rev. B
Hotlogic Operational Codes
Hotlogic Components
1 To power
2 To compressor
3 Power LED
4 Sensor LED
5 Output LED
6 To ambient sensor
7 To pressure switch
8 To tank sensor
9 To fan
5
8
9
7
6
4
3
2
1
LED 1
(Power)
LED 2
(Sensor)
LED 3
(Output)
Explanation
Alternating Off Power on initialisation (LEDs blink Red-Green alternately)
Green Green Green Fan on (Compressor on/off)
Green Flashing Red Off Sensor error (1 blink = ambient sensor, 2 blinks = tank sensor)
Green Green Red Over Pressure Switch tripped