46
R2K 55 - RAD - ING - Inst.Manual - 2002.1_CSA
2. FIRST START-UP
SUPPORT CENTER
PARAMETER DESCRIPTION RANGE FUNCTION
P15 ANTI-LEGIONELLA FUNCTION
(ONLY FOR ACCUMULATION BOILER)
THROUGH THIS PARAMETER YOU CAN ACTIVATE/DEACTIVATE
ANTI LEGIONELLA” HEAT TREATMENT OF THE ACCUMULATION
BOILER. EVERY 7 DAYS THE WATER TEMPERATURE INSIDE THE
ACCUMULATION BOILER IS HEATED BEYOND 140 °F (60 °C) THUS
GENERATING A BURNING HAZARD. KEEP UNDER CONTROL
SUCH DOMESTIC HOT WATER TREATMENT (AND INFORM THE
USERS) TO AVOID UNFORESEEABLE DAMAGES TO PERSONS,
ANIMALS, PROPERTY. A THERMOSTATIC VALVE SHOULD BE
INSTALLED AT THE DOMESTIC HOT WATER OUTLET TO AVOID
ANY BURNS.
0 - 1 0 = DISABLED
1 = ENABLED (PRE-SET BY
DEFAULT ON ACCUMULATION
BOILERS)