The Rainbow Quantum Micro-Injector represents
a new era in tree injection design and battery-
powered performance for the care of urban
ecosystems. The Quantum protects trees from
deadly pests while doing minimal harm, using a
variable pressure system and plug-less tips. It is
lightweight, accurate, and able to work all day.
www.RainbowEcoscience.com/quantum
Digital Download of this Manual Available at:
Manual
Ordering & Tech Support: 877-272-6747 www.RainbowEcoscience.com
Or scan here for the "How To" video
Question and Answer IconNeed help?

Do you have a question about the Rainbow Quantum and is the answer not in the manual?

Overview

The Rainbow Quantum Micro-Injector is a battery-powered device designed for tree injection in urban ecosystems. Its primary function is to protect trees from pests by delivering treatments with minimal harm, utilizing a variable pressure system and plug-less tips. The device is engineered for lightweight operation, accuracy, and extended use throughout the day.

Technical Specifications and Components:

The Quantum Micro-Injector system includes several key components:

  • 1 x 20 V Battery: Provides the power for the device, requiring at least 24 hours of initial charging before use.
  • 1 x Battery Charger: For recharging the 20 V battery.
  • 1 x Floating Injection Tee: A crucial component for connecting to the tree and delivering the product.
  • 1 x 14' Self-Retracting Coiled 5/32" OD Tube: Connects the floating injection tee to the device, allowing for flexible movement during operation.
  • 2 x Product Reservoirs with Caps, Fittings, Filters: These clear reservoirs hold the product to be injected, allowing users to monitor product levels. They are designed to be securely locked into position on the device.
  • 1 x Coiled Tubing Clip with Injection Tee Holster: Helps manage the coiled tubing and provides a secure place for the injection tee when not in use.
  • 2 x 15/64" High Helix Drill Bits: Used for drilling injection sites into trees.
  • 1 x Quantum Maintenance Kit: Contains essential items for device upkeep.
  • 1 x Quantum Manual: The comprehensive guide for operation and maintenance.
  • 1 x Storage Bag: For convenient storage and transport of the device and its components.
  • 1 x Carrying Strap: Enhances portability.
  • 1 x Reservoir Labels: For identifying the contents of the reservoirs.
  • 1 x 10ml Measuring Cylinder: Used for precise calibration of product dosage.

Approved Products for Use:

The Quantum Micro-Injector is approved for use with a range of products, including:

  • Mectinite
  • Arbormectin
  • Transtect Infusible
  • Xytect 10%
  • Bacastat
  • Lepitect Infusible

Usage Features:

  • Setup:

    • Charge the 20V battery for at least 24 hours.
    • Connect the floating tee to the device by inserting one end of the coiled tubing into the ball valve on the back of the injection tee handle.
    • Connect the other end of the tube into the straight push-to-connect fitting on the side of the device.
    • Insert a fully charged battery; the display will automatically turn on, and the device will be in 'injection mode' setting.
  • Priming:

    • Ensure the reservoir is fully locked into position and filled with the product.
    • Select 'prime mode' using the left or right buttons.
    • Remove the plug from the reservoir priming port and insert the injection tee tip into the port. Turn the ball valve to the open position.
    • Press the start/pause button to allow product to flow until visible air bubbles are cleared from the tubes.
    • After priming, switch back to 'injection mode'.
  • Calibration:

    • Calibration should be performed at the start of the day and when changing products.
    • Select 'purge mode' using the left or right arrows.
    • In calibration mode, insert the injection tip into a graduated cylinder and press start to inject a 10 ml dose.
    • Enter the actual amount of product injected into the cylinder using the up or down arrows and press reset.
    • Repeat the 10 ml calibration dose until the device distributes an accurate 10 ml dose, repeating two more times for accuracy confirmation.
  • Injecting:

    • Drilling Injection Sites: Drill into root flares as close to soil grade as possible, avoiding cavities or rot. Use a 15/64" high helix drill bit to a depth of 3/4" to 1", perpendicular to the bark surface.
    • Determining Dose: Calculate the amount of product per injection site by dividing the total amount needed for the tree by the number of injection sites (DBH/2).
    • Setting Dose: In 'injection mode', use the up or down arrows to adjust the ml of dose per injection site.
    • Injection Process: Insert the tip into the tree by turning clockwise until it seats firmly. Open the ball valve on the injection tee and press the start button. The screen will turn green, displaying current PSI. When complete, the screen turns red, showing the total dose injected. The device will beep 5 times when pressure drops below 10 psi.
    • Finishing Injection: After completing injections, close the ball valve and insert the tee into the device holsters. The device can be put into sleep mode by pressing the power on/off button for 5 seconds.
  • Resetting Injection Dose: Press the reset button (also power on/off button) once to reset the total amount injected and the number of doses, and again to reset the 10 ml injection dose and total volume injected.

  • Purging Product from Lines: Open the ball valve on the tee handle and ensure the reservoir is fully inserted. Switch to 'purge mode' using the arrows. Press start/pause to run the pump backward, purging product back into the tank.

Maintenance Features:

  • Daily Cleaning:

    • Thoroughly clean the device with a gentle cleanser to remove chemical residue.
    • Rinse the device with at least 200 ml of water at the end of each workday. For Xytect 10%, use alcohol to flush the system.
    • After adding water, remove the reservoir, swish the water for 5-10 seconds, and reinsert.
    • Start the priming sequence until lines are completely void of water.
    • Air dry the device.
    • Remove the battery.
  • Weekly Cleaning:

    • Complete daily cleaning steps.
    • Remove the reservoir, cap, cap gasket, and filter, allowing them to air dry.
    • Add silicone-based lubricant to the valve and place the reservoir mouth down for air drying.
    • Lubricate the female valve on the tank reservoir and the male valve on the pump inlet.
    • Remove the battery.
    • Store the device in a controlled indoor environment.
  • After Heavy Use: Follow all cleaning and lubrication protocols to maximize the longevity of rubber seals and components.

  • Season Wrap Up/Long-Term Storage Cleaning:

    • Complete daily and weekly steps.
    • Increase water to 500 ml for rinsing.
    • Add lubricant to the valve and place the reservoir mouth down for air drying.
    • Ensure the device is rinsed out and emptied of all moisture, allowing 24 hours for air drying before storing.
  • General Recommendations:

    • Calibrate the device at the start of the day and when changing products.
    • Do not let batteries fully drain.
    • Charge batteries daily, preferably after the end of the day and leave charging overnight.
    • Do not leave product inside the pump, system, and tubing while storing the device.
    • Always rinse out the device when switching between different products.
    • Store above 32°F (0°C) and below 110°F (43°C).

Repair Instructions:

  • Replacing Set Screws/Tightening Injector Tee Tips:

    • Loosen the set screw with a small flathead screwdriver. Replace if worn.
    • Use a 9/16" wrench to tighten the tip clockwise.
    • If a threaded part won't turn, give a slight turn in the opposite direction to loosen the seal. Avoid over-tightening.
    • Place in a controlled indoor environment.
  • Replacing or Removing the Fill Cap Gasket:

    • Remove the gasket and filter from the reservoir mouth.
    • The filter can be popped out of the gasket for cleaning.
    • To replace, add the gasket to the reservoir mouth before inserting the filter.
  • Replacing the Priming Port:

    • Remove the plug by gently pulling.
    • Reinsert the T-shaped end by squeezing and gently pushing it back into place.
  • Repairing or Replacing Tubing:

    • Disconnect tubing by pushing the plastic collet of the push-to-connect fitting and simultaneously pulling out the tube.
    • If needed, cut off about 1/4" - 1/2" from the ends of the tubing with a sharp razor knife to ensure a straight edge.
    • Inspect tubing ends for chemical residue, deep scoring, and kinks. Replace damaged tubing if necessary.
    • Removing Cut Off Tube From Ball Valve: Gently remove the blue collet push-to-connect part, then pull back the teeth until parallel with the valve walls. Gently pry out the cut tubing (do this carefully). After removing the tube, push the teeth back into place and then push the blue collet back into the ball valve.
  • Replacing Ball Valve:

    • Disconnect tubing.
    • Use a 9/16" wrench to loosen the ball valve counter-clockwise until completely removed.
    • Clean inside the tee.
    • Apply pipe sealant to the threads of the ball valve and insert into the injection handle, turning clockwise until hand tight.
    • Insert tubing into the push-to-connect fitting.
  • Cleaning the Device Valve:

    • Clean the valve on the pump with a rag or cleansing wipe.
    • Use a small pipe cleaning brush and/or cleansing wipe to clean inside the valve on the reservoir.
    • Lubricate valves with silicone-based lubricant.

Rainbow Quantum Specifications

General IconGeneral
BrandRainbow
ModelQuantum
CategoryLawn and Garden Equipment
LanguageEnglish