Raisecom
ISCOM5508-GP (A) Hardware Description
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
26
Figure 3-3 FC/PC fiber connector
When connecting or removing the FC/PC fiber connector, align the connector with the optical
interface, and do not rotate the fiber. Operate as below:
To connect the fiber, align the fiber head with the optical interface. Be careful not to
damage the ceramic tube inside the optical interface. After snapping the fiber in place,
rotate the screw sleeve clockwise to fasten the optical interface.
To remove the fiber, rotate the screw sleeve counterclockwise. When the screw sleeve is
loosened, pull the fiber out.
3.1.3 Wiring
Table 3-3 lists the wiring of the fiber.
Table 3-3 Wiring of the fiber
Wiring Local optical interface
Direction of
optical signals
Peer optical interface
Single-fiber
connection
Optical interface <-> Optical interface
Dual-fiber
connection
Optical interface Tx -> Optical interface Rx
Optical interface Rx <- Optical interface Tx
3.2 Ethernet cable
3.2.1 Introduction
The Ethernet cable of the ISCOM5508-GP can be used to:
Connect the Ethernet electrical interface of the ISCOM5508-GP to other devices.
Connect the SNMP of the ISCOM5508-GP to the NView NMS system.