Batterypacksdorequireroutinemaintenanceandcaretomaximizetheirusefullifeand
maintainwarrantycoverage.Readandfollowtheguidelinesinthismanualtosafelyuse
yourlithium-ionbatterypacksandachievebatterylifespan.
Lithium-Ion Battery Maintenance Guidelines
Accordingtoleadingcellmanufacturers(LG,Samsung,Panasonic),theestimatedlifeofa
lithium-ionbatteryis500chargecycles.Whenstatingapproximateusefullifeofabattery
inunitsof“chargecycles,”cellmanufacturersdenethisasthepointwherethebattery
capacity(Ah)isreducedto80%oforiginal.Thismeansbatteryisnot“dead”after500
chargecycles,butruntimeissignicantlyreduced,andreplacementshouldbeconsidered.
Partialdischargeoflithium-ionbatteriesisne.Thereisno“memoryeect”andthebattery
doesnotneedperiodicfulldischargecyclestoprolonglife.
Overview
Storage
Whenstoring,removebatterypacksfromfanandstoreinadryandcoollocation.Avoid
extremetemperatures.
RecommendedStorageTemperature:5
o
C to 20
o
C(41
o
Fto68
o
F)
Maximumrelativehumidityduringstorage:90%RH
NOTE:allbatteriesself-dischargeduringstorage.Highertemperature(>20
o
C or 68
o
F)reduce
thebatterystoragelife.
Lithium-ionbatteriesshouldbestoredinachargedstate,ideallyaround30%stateof
charge(SoC).See“Storage/TransportMode”sectionofthismanualforeasydischarging
stepstofollowbeforestoringbatterypacks.
Long-term(>6months)storageofbatterypacksisnotrecommended.Whenabatterypack
hasbeenunusedfor6months,checkthechargestatusandeitherchargeordisposeofthe
batteryasappropriate.
Recommendations
Batterypackswilllastsignicantlylongerwhenruninpairs(twobatterypacksperfan)
asthereis50%lessdischargecurrentperpack.
Aswithanyequipment,batterieswillwearoutfasterwithheavyuse.Depthof
Discharge(DoD)determinesthecyclecountofthebattery.Thesmallerthedischarge
(lowDoD),thelessstressisenactedonthechemistryofthebatteryandthelongerthe
batterywillultimatelylast.Ideally,operatorsshouldavoidfulldischargesandcharge
thebatteryaftereveryuse.
Maintenance and Disposal
DONOTdisassembletheventilatorformaintenancereasons.
DonotloosenscrewsoncontrolboxwithoutcontactingEuramcocustomerservice.
Theyaretorquedtoasettingtoachievewatertightness.
Completelyunravelpowercordandplaceunitonaat,stablesurface.Cleanventilator
periodicallytoremoveaccumulateddustorparticlesfromventilatorguards,impeller
bladeandheatsinkinrearofcontroller(ribbed).Useonlybiodegradabledetergents.If
powerwashing,avoidcontrollerhousingespeciallygasketsandcontrolpanel.
Contactfactoryforreplacementpartsandinstallationinstructions.Toorderspare
partscallEuramcoGroup+1.619.670.9590 or theteam@euramco.com
Alwaysdisposeofyourbatterypackaccordingtofederal,stateandlocalregulations.
Evendischargedbatteriescontainsomeenergy.Beforedisposingof,useelectricaltape
tocovertheterminalstopreventthebatterypackfromshortcircuit.
Properlydisposeofbatterypackswhennecessary.Contactyourlocalhazardous
materialse-wastecollectiondepartmentfordetailsorproperdisposalofrechargeable
batteries.