EasyManua.ls Logo

R&S ESR7 - 11.4.1 Measurements and Result Displays; 11.4.1.1 Display Configuration; 11.4.1.2 Bargraph Control

R&S ESR7
1126 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Control
R&S
®
ESR
637User Manual 1175.7068.02 ─ 12
● Test Automation.................................................................................................... 673
● Working with Markers............................................................................................687
● Limit Lines.............................................................................................................703
11.4.1 Measurements and Result Displays
● Display Configuration............................................................................................637
● Bargraph Control...................................................................................................637
● Scan Control......................................................................................................... 640
● Final Measurements and Automated Test Sequence Control...............................642
● Trace Data and Result Query............................................................................... 643
● Fixed Frequency Scans........................................................................................ 647
● Demodulating Analog Signals...............................................................................648
● Spectrogram Control.............................................................................................649
11.4.1.1 Display Configuration
CALCulate<n>:FEED..................................................................................................... 637
CALCulate<n>:FEED <ResultDisplay>
This command selects the result display.
Suffix:
<n>
.
1...3
Selects the measurement window.
Parameters:
<ResultDisplay> 'NONE'
Removes the window selected with the suffix <n>.
'XTIM:SPECtrum'
Selects the IF analysis result display.
'XTIM:BARGraph'
Selects the bargraph.
Note that the Bargraph always has to be in window 1.
'XFRequency[:SPECtrum]'
Selects the scan result display.
'XFRequency:SGRam'
Selects the spectrogram result display.
Note that you can add a spectrogram only if you have already
turned on either Scan or IF Analysis. If you are displaying Scan
and IF Analysis simultaneously, the Spectrogram is unavailable.
11.4.1.2 Bargraph Control
DISPlay:BARGraph:LEVel:LOWer?..................................................................................638
DISPlay:BARGraph:LEVel:UPPer?.................................................................................. 638
DISPlay:BARGraph:PHOLd[:STATe].................................................................................638
Remote Commands in Receiver Mode

Table of Contents