EasyManua.ls Logo

R&S RTO - Timeout

R&S RTO
829 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Mixed Signal Option (MSO, R&S RTO-B1)
R&S
®
RTO
336User Manual 1316.0827.02 ─ 06
11.3.4.4 Timeout
The timeout trigger event checks if the trigger source signal stays above or below the
threshold voltage for a specified time lapse. In other words, the event occurs if the state
condition remains unchanged for the specified time.
You can use the timeout trigger on a single digital channel, or a logical combination of
digital channels.
Fig. 11-4: Timeout trigger settings for trigger source = logical combination of digital channels
Range
Sets the state condition:
"Stays high"
The level of a digital channel stays above the threshold, or the logical
expression for "Logic" trigger source is true.
"Stays low"
The level of a digital channel stays below the threshold, or the logical
expression for "Logic" trigger source is false.
"High or low"
The signal state remains unchanged.
SCPI command:
TRIGger<m>:PARallel:TIMeout:RANGe on page 747
Time
Defines the time limit for the timeout at which the instrument triggers.
SCPI command:
TRIGger<m>:PARallel:TIMeout:TIME on page 747
Logical expression
Defines a logic combination of several digital channels as trigger condition if "Logic" is
set for "Source". The "Qualification Editor" supports the entry of the expression.
SCPI command:
TRIGger<m>:PARallel:TIMeout:EXPRession[:DEFine] on page 744
TRIGger<m>:PARallel:STATe:EXPRession[:DEFine] on page 744
TRIGger<m>:PARallel:PATTern:EXPRession[:DEFine] on page 744
TRIGger<m>:PARallel:SPATtern:EXPRession[:DEFine] on page 744
Reference for MSO

Table of Contents

Related product manuals