Parameters:
<Polarity> POSitive | NEGative | EITHer
See chapter 16.2.2.4, "Polarity Parameter", on page 420.
*RST: POSitive
TRIGger<m>:LEVel<n>:RUNT:UPPer <Level>
Sets the upper voltage threshold.
Suffix:
<m>
.
1..3
Indicates the event in a trigger sequence: 1 = A-event, 2 = B-event,
3 = R-event.
<n> 1..9
Indicates the trigger source:
1...4 = channel 1...4
5...9 = not available
Parameters:
<Level> Range: -10 to 10
Increment: 1E-3
*RST: 0.1
Default unit: V
TRIGger<m>:LEVel<n>:RUNT:LOWer <Level>
Sets the lower voltage threshold.
Suffix:
<m>
.
1..3
Indicates the event in a trigger sequence: 1 = A-event, 2 = B-event,
3 = R-event.
<n> 1..9
Indicates the trigger source:
1...4 = channel 1...4
5...9 = not available
Parameters:
<Level> Range: -10 to 10
Increment: 1E-3
*RST: -0.1
Default unit: V
TRIGger<m>:RUNT:RANGe <Mode>
Defines the time limit of the runt pulse in relation to the TRIGger<m>:RUNT:WIDTh and
TRIGger<m>:RUNT:DELTa settings.
Command Reference