Parameters:
<Boolean> ON – command sequence stored to file
C:\Users\Public\Documents\Rohde-Schwarz\ZNA\
RemoteLog\VNARemote.log.
OFF – command sequence not logged.
Example: 
SYST:LOGG:REM ON
Enable remote logging. The log file
'C:\Users\Public\Documents\Rohde-Schwarz\ZNA\
RemoteLog\VNARemote.log' is fixed and does not have to
be specified.
SYSTem:OPTions:FACTory
Resets the response to the *OPT? query to the factory default value. This command
overwrites a user-defined option string; see example.
Example: 
SYSTem:OPTions:STRing 'MyOptions'; *OPT?
Define an identity string. The response is MyOptions.
SYSTem:OPTions:FACTory; *OPT?
Re-activate the factory setting. The analyzer returns a comma-
separated list of software and hardware options.
Usage:  Event
Manual operation:  See "Define *IDN + *OPT..." on page 815
SYSTem:OPTions[:STRing] <Options>
Defines an option string for the network analyzer. The query is equivalent to *OPT?.
Parameters:
<Options> String parameter containing the available options
Example:  See SYSTem:OPTions:FACTory
Manual operation:  See "Define *IDN + *OPT..." on page 815
SYSTem:PASSword[:CENable] <Password>
Sends a password to the analyzer enabling a class of service functions to function
(Command ENable). Service functions are activated with the commands of the
DIAGnostic... system and should be used by a R&S service representative only.
Setting parameters: 
<Password> Case-sensitive string variable. Sending an invalid password gen-
erates error -221, (settings conflict).
Example: 
SYST:PASS "XXXX"
Enter password.
Usage:  Setting only