Covers general installation/usage warnings and specific gas unit hazards.
Details measures to take in case of gas smell to prevent explosion.
Provides meanings for danger, warning, attention, corrosive, fire, burning, and voltage icons.
Initiating an automatic self-test to adapt the unit to environmental conditions.
Emphasizes securing the unit against tilting and observing weight for safety.
Specifies minimum 50mm clearance on left, right, and rear for most units.
Instructions for installing table units on original stands or pedestals.
Securing the unit to the floor using supplied floor locks.
Units require independent fused power supply and permanent electrical connection.
Use NEC UL standard power cord; terminals in electrical compartment.
Gas units have a power cable with plug; polarity must be observed.
Detailed steps for converting between 208/240V and 440/480V supply voltages.
Check terminal fit, comply with regulations, use earth leakage circuit breaker.
Connect to drinking water quality; maximum temperature 86°F.
Treated water must not have hardness less than 5 gr/gal to prevent corrosion.
Burner settings must conform to installation conditions; CO/CO2 analysis is required.
Ensure gas supply and distribution are leak-free; connect via locally approved installer.
Rooms must be well-ventilated to prevent harmful combustion product build-up.